Home / Display & Electronics Manufacturing
APPLICATION GUIDE

Display & Electronics Manufacturing

Glass-substrate stages, inspection guides and precision placement fixtures

Methods

Procedure

  1. Define support and vacuum state
  2. Establish references
  3. Record stage orientation
  4. Adjust and lock
  5. Recheck repeatability

Loaded deformation of thin or flexible glass needs separate measurement; base geometry is not the complete substrate form.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗

Recommended instruments

STEP BY STEP

Understand the measurement step by step

  1. 01

    Define support and vacuum state

  2. 02

    Establish references

  3. 03

    Record stage orientation

  4. 04

    Adjust and lock

  5. 05

    Recheck repeatability

Principle schematic · not to scale
1 / 4
  1. Fix loading state · Fix support conditions and measurement direction; record whether glass is loaded, the vacuum setting and temperature.
  2. Record vacuum off · Mount the reflector on a rigid stage datum and record a stable angle and reference zero with vacuum off.
  3. Apply vacuum and reread · Apply the specified vacuum under the equipment procedure, wait for pressure and mechanical settling, read the same component and switch vacuum off to check return.
  4. Separate direction and form · Convert the state difference to equivalent directional displacement at the stated lever arm while checking local substrate form independently.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Display-substrate stage direction before and after vacuum loading

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project. All numbers are constructed examples. Compare one angular component of a rigid display-panel fixture with vacuum off and on. Thin-glass bending requires independent surface measurement and cannot be inferred directly from stage angle.

Setup and preparation

  • Fix support conditions and measurement direction; record whether glass is loaded, the vacuum setting and temperature.

  • Mount the reflector on a rigid stage datum and record a stable angle and reference zero with vacuum off.

  • Apply the specified vacuum under the equipment procedure, wait for pressure and mechanical settling, read the same component and switch vacuum off to check return.

  • Convert the state difference to equivalent directional displacement at the stated lever arm while checking local substrate form independently.

Example data and records

  • Vacuum-off angle 0.6″; vacuum-on angle 1.1″; difference 0.5″.

  • Lever arm for directional conversion: 150 mm.

  • No glass-form data are supplied in this example; glass deformation is not inferred.

Calculation steps

Δθ=1.1−0.6=0.5″; e=150×tan(0.5π/648000)×1000≈0.3636 μm.

Interpretation

The difference corresponds to about 0.364 μm equivalent directional displacement at 150 mm. It excludes stage translation, local suction deformation and glass warpage.

Verification and pitfalls

  • Record pressure settling time and loading conditions; do not combine different states as one test.

  • Verify attachment to a rigid datum rather than a flexible cover.

  • Acquire vacuum-release return and repeated loading cycles separately.