MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Research Facilities & Beamline Assembly
APPLICATION GUIDE

Research Facilities & Beamline Assembly

Experimental stages, beamline support structures and optical-element datums

Methods

Procedure

  1. Define local and global coordinates
  2. Establish traceable references
  3. Measure stations and overlaps
  4. Compare closure relationships
  5. Archive adjustments and verification

This guide concerns stopped mechanical/optical assembly; beam, vacuum and radiation operations require facility procedures.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗

Recommended instruments

STEP BY STEP

Understand the measurement step by step

  1. 01

    Define local and global coordinates

  2. 02

    Establish traceable references

  3. 03

    Measure stations and overlaps

  4. 04

    Compare closure relationships

  5. 05

    Archive adjustments and verification

ABCDΔh_ABΔh_BCΔh_CDΔh_DAc = ΣΔhA → B → C → D → APrinciple schematic · not to scale
1 / 4
  1. Permit and common marks · Enter the stopped assembly area under the facility permit procedure, define stations A and B and three stable common marks, and record coordinates and time.
  2. Raw station observations · Independently verify matching station directions, then observe all three common marks from each station and retain raw station heights.
  3. Estimate offset and tilt · Calculate B−A at each mark and estimate the constant zero offset; inspect residuals for position-dependent tilt.
  4. Independent verification · Subtract the estimated offset from B and verify independent check marks; if orientation differs, use a suitable rigid-body or plane model instead of a constant shift.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Teaching height-datum stitching between overlapping beamline-support stations

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project. All numbers are constructed examples. During stopped mechanical maintenance, use three common points to transfer a height zero between stations. Only a constant offset with independently verified common orientation is demonstrated; beam, radiation and vacuum operations are outside scope.

Setup and preparation

  • Enter the stopped assembly area under the facility permit procedure, define stations A and B and three stable common marks, and record coordinates and time.

  • Independently verify matching station directions, then observe all three common marks from each station and retain raw station heights.

  • Calculate B−A at each mark and estimate the constant zero offset; inspect residuals for position-dependent tilt.

  • Subtract the estimated offset from B and verify independent check marks; if orientation differs, use a suitable rigid-body or plane model instead of a constant shift.

Example data and records

  • A-station common-point heights in μm: [2,4,6].

  • B heights in μm: [7,9,11]; every B−A difference equals 5 μm.

  • Identical differences are deliberately constructed for teaching and are not evidence of zero uncertainty.

Calculation steps

Constant offset b=mean(Bᵢ−Aᵢ)=(5+5+5)/3=5 μm; B′=B−b=[2,4,6] μm, giving zero residual at the three common points.

Interpretation

Under the stated common-orientation teaching model, subtracting 5 μm aligns the common-point heights. Zero residual means these points fit the chosen model, not that real datum transfer is error-free.

Verification and pitfalls

  • Use check marks excluded from the solution for independent verification.

  • Insufficient point distribution or directional constraints cannot establish full six-degree-of-freedom alignment from one offset.

  • Facility-authorized personnel must follow separate beam, vacuum and radiation procedures; this guide covers stopped geometric assembly only.