MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Surface plate flatness inspection plan
DOWNLOADABLE MEASUREMENT PLAN

Surface plate flatness inspection plan

For macroscopic plates, tables and mounting surfaces. Slope integration and direct height measurements require different data inputs.

Instruments

Procedure

Calculation

Slope readings require integration and a common reference across lines. Direct heights use point coordinates. Least-squares plane residual peak-to-valley must not be labelled minimum-zone flatness.

Reporting

Limitations

Sparse sampling may miss local defects. This plan does not replace optical interferometry or roughness measurement.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Define coordinates, useful area, supports and direct-height measurement. The nine-point grid is illustrative; actual density must reflect the risk of local surface features.

  2. 02

    Set nodes where x and y each equal 0, 100 or 200 mm, record a common height reference and keep supports unchanged.

  3. 03

    Acquire all nine heights while rechecking one fixed reference. Multi-line systems must unify datums before producing this type of height matrix.

  4. 04

    Fit the least-squares plane z=ax+by+c and subtract its height at each node to obtain nine signed residuals.

  5. 05

    Plot the grid and residual map, identify extreme points and unsampled regions; do not invent measured detail between nodes.

  6. 06

    Deliver raw coordinates, fitted coefficients, residuals, algorithm, coverage limits and uncertainty. Use a separate appropriate evaluation if the contract requires minimum-zone flatness.

Principle schematic · not to scale
1 / 6
  1. Define measurement model · Define coordinates, useful area, supports and direct-height measurement. The nine-point grid is illustrative; actual density must reflect the risk of local surface features.
  2. Set nine-point grid · Set nodes where x and y each equal 0, 100 or 200 mm, record a common height reference and keep supports unchanged.
  3. Acquire common-datum heights · Acquire all nine heights while rechecking one fixed reference. Multi-line systems must unify datums before producing this type of height matrix.
  4. Fit plane and residuals · Fit the least-squares plane z=ax+by+c and subtract its height at each node to obtain nine signed residuals.
  5. Show sampling limits · Plot the grid and residual map, identify extreme points and unsampled regions; do not invent measured detail between nodes.
  6. Deliver model and data · Deliver raw coordinates, fitted coefficients, residuals, algorithm, coverage limits and uncertainty. Use a separate appropriate evaluation if the contract requires minimum-zone flatness.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

3×3 table grid: teaching surface form after removing overall tilt

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project. Nine direct-height points on a 200 mm×200 mm area illustrate least-squares plane fitting. They already share one height datum; this is a direct-height model, not angular readings treated as heights. A sparse teaching grid cannot establish complete table acceptance.

Setup and preparation

  • Define coordinates, useful area, supports and direct-height measurement. The nine-point grid is illustrative; actual density must reflect the risk of local surface features.

  • Set nodes where x and y each equal 0, 100 or 200 mm, record a common height reference and keep supports unchanged.

  • Acquire all nine heights while rechecking one fixed reference. Multi-line systems must unify datums before producing this type of height matrix.

  • Fit the least-squares plane z=ax+by+c and subtract its height at each node to obtain nine signed residuals.

  • Plot the grid and residual map, identify extreme points and unsampled regions; do not invent measured detail between nodes.

  • Deliver raw coordinates, fitted coefficients, residuals, algorithm, coverage limits and uncertainty. Use a separate appropriate evaluation if the contract requires minimum-zone flatness.

Example data and records

  • Coordinates x and y each take 0, 100 and 200 mm.

  • Height rows at y=0, 100, 200 mm (μm): [1,−1,3]; [0,7,2]; [5,3,7].

  • All heights are synthetic and already share a datum.

Calculation steps

The least-squares plane is z=0.01x+0.02y+0, with z in μm and x,y in mm. Residual rows are [1,−2,1]; [−2,4,−2]; [1,−2,1] μm. Their mean and first moments with x and y are zero. Sampled residual peak-to-valley=4−(−2)=6 μm.

Interpretation

The nine-point residual peak-to-valley relative to the least-squares plane is 6 μm. It is a result for this algorithm and grid, not automatically minimum-zone flatness or proof that unsampled regions are defect-free.

Verification and pitfalls

  • All points must share one height datum; independently zeroed rows cannot simply be stitched together.

  • Support and load changes can alter form; retain the prescribed and documented state.

  • Surface form, surface roughness and optical wavefront quality are separate tasks.