Home / Optical metrology teaching and laboratory plan
DOWNLOADABLE MEASUREMENT PLAN

Optical metrology teaching and laboratory plan

Reproducible exercises for autocollimation, angular conversion, profile reconstruction and error evaluation. Keep example data separate from measured records.

Instruments

Procedure

Calculation

1 arcsecond = π/648000 radians. For a teaching example with L = 100 mm and θ = 1 arcsecond, Δh is approximately 0.484814 μm. This example is not an accuracy claim.

Reporting

Limitations

Teaching calculations are not calibration certificates. The instructor defines supervision, difficulty and operating limits.

STEP BY STEP

Understand the measurement step by step

  1. 01

    The instructor defines one reading per interval and sets both effective reflector span and sampling step to 100 mm; supply demonstration angles, not field measurements.

  2. 02

    Convert 1″ to π/648000 rad and convert [+1,+1,−1]″ into three height increments, retaining enough decimal places.

  3. 03

    Accumulate four station heights from initial zero, keeping raw angles, distance units and positive direction; do not independently rezero intermediate stations.

  4. 04

    Subtract the line through the endpoints, then fit a least-squares line to the same four heights; list both residual sequences and peak-to-valley values.

  5. 05

    Compare results and explain that least squares minimizes squared residuals, not their range; submit calculations, unit checks and omitted uncertainty sources.

Principle schematic · not to scale
1 / 5
  1. Define sampling geometry · The instructor defines one reading per interval and sets both effective reflector span and sampling step to 100 mm; supply demonstration angles, not field measurements.
  2. Convert angles to height · Convert 1″ to π/648000 rad and convert [+1,+1,−1]″ into three height increments, retaining enough decimal places.
  3. Accumulate four stations · Accumulate four station heights from initial zero, keeping raw angles, distance units and positive direction; do not independently rezero intermediate stations.
  4. Residuals for two references · Subtract the line through the endpoints, then fit a least-squares line to the same four heights; list both residual sequences and peak-to-valley values.
  5. Explain metric differences · Compare results and explain that least squares minimizes squared residuals, not their range; submit calculations, unit checks and omitted uncertainty sources.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Classroom comparison of two references for the same angular dataset

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project. All data are constructed examples. Three constructed interval angles teach arcsecond conversion, accumulated heights, endpoint reference and least-squares reference. Students calculate manually before checking with the website tool and see why reference choice changes residual metrics.

Setup and preparation

  • The instructor defines one reading per interval and sets both effective reflector span and sampling step to 100 mm; supply demonstration angles, not field measurements.

  • Convert 1″ to π/648000 rad and convert [+1,+1,−1]″ into three height increments, retaining enough decimal places.

  • Accumulate four station heights from initial zero, keeping raw angles, distance units and positive direction; do not independently rezero intermediate stations.

  • Subtract the line through the endpoints, then fit a least-squares line to the same four heights; list both residual sequences and peak-to-valley values.

  • Compare results and explain that least squares minimizes squared residuals, not their range; submit calculations, unit checks and omitted uncertainty sources.

Example data and records

  • Interval angles in arcseconds: [+1,+1,−1]; step and effective span L=100 mm.

  • Positive increment a=100×tan(π/648000)×1000≈0.484813681 μm; station heights [0,a,2a,a].

  • Endpoint residuals/a=[0,2/3,4/3,0]; least-squares residuals/a=[−0.4,0.2,0.8,−0.6].

Calculation steps

For station index i=0,1,2,3, hfit/a=0.4+0.4i. Endpoint residual PV=4a/3≈0.646418 μm; least-squares residual PV=1.4a≈0.678739 μm. Neither is automatically a minimum-zone result.

Interpretation

Different references give different residual peak-to-valley values for the same profile, and the least-squares value need not be smaller. The example verifies calculation definitions, not instrument accuracy or workpiece acceptance.

Verification and pitfalls

  • Check the factor of 1000 from mm to μm and the conversion from arcseconds to radians.

  • Verify the interval-angle, support-span and step convention; use a different reconstruction model when sampling geometry differs.

  • Label demonstration data, real readings, statistical uncertainty and calibration certificates separately.