Principle
Along each measurement line the autocollimator records small tilts of the reflector base, and the angles are integrated into heights with Δh=L·tanθ. The two diagonals are measured first; equating their endpoints defines an interim reference plane. Perimeter and intermediate parallel sections are then measured and transformed onto that plane. The resulting point cloud supports flatness evaluation against the agreed reference.
Preparation
Define the surface size, tolerance, and a layout of diagonals, perimeter and intermediate sections with section spacing equal to an integer multiple of the base span. Clean the surface and record the measured support span of the reflector base. Verify autocollimator calibration, return-beam brightness and thermal stability; avoid one-sided sunlight or draughts.
Workflow diagram
Procedure
- Draw the layout so that section spacing equals the base span; number every station on both diagonals, the perimeter and the intermediate sections.
- Measure the diagonals first: step the reflector base along each diagonal, record stable readings and integrate to the end-point height differences.
- Define the reference plane by equating the diagonal endpoints, then measure the perimeter and intermediate sections.
- Unify each section to the datum: align it at the intersections with the diagonals and shift the whole section accordingly.
- Check the closure error of points shared by crossing sections; re-measure the offending segments if it is excessive.
- Assemble all point heights, evaluate flatness against the agreed reference and report the result with uncertainty.
Calculation
Per station: θrad=θ″·π/648000 and Δh=L·tan(θrad), with L the measured span in mm (×1000 for μm). Equating diagonal endpoints fixes the datum; each section is shifted by its intersection offset: z′i=zi+δ. Flatness is then evaluated against the agreed reference such as the minimum zone.
Illustrative example
Teaching data, not measured: on an 800 mm × 500 mm plate with L=100 mm a diagonal has about 10 stations. If the integrated end difference is +2.4 μm, the datum correction is −1.2 μm at each end. A section whose intersection mismatch is +0.3 μm is shifted by −0.3 μm. These numbers only illustrate the workflow.
Limitations
- If the measured diagonals deviate from the geometric ones, the closure relations break down.
- A base span that is not an integer fraction of the section spacing misaligns the integrated nodes.
- Treating the interim-datum result as the minimum-zone flatness value.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.