MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Flatness by the Grid (Union Jack) Layout
MEASUREMENT METHOD

Flatness by the Grid (Union Jack) Layout

Evaluate the flatness of plates, bases and machine tables, especially where dense sampling or grid-based acceptance is required. The grid and union-jack layouts provide redundant lines whose closure errors expose local reading or integration mistakes. They suit medium-size surfaces accessible in both directions.

Principle

The autocollimator records the tilt sequence of the reflector base along every line, and each line is integrated into a height profile. A datum line (usually the central longitudinal line) is measured first; transverse sections link the parallel lines to it and place every line on a common coordinate frame. The union-jack layout adds centre lines to the diagonals for more crossings. At each crossing the two lines give two values whose difference is the closure error, a check of consistency.

Preparation

Draw the grid with row and column spacing equal to, or an integer multiple of, the base span. Fix the datum line and connection order so that every parallel line links to the datum through at least one transverse section. Clean the surface, measure the span and confirm adequate return light on the longest line.

Workflow diagram

01Draw the grid02Datum line03Parallel lines04Transverse links05Closure check06Evaluate flatness

Procedure

  1. Plan row and column spacing as integer multiples of the span; number the stations and fix the datum line and direction of every line.
  2. Measure and integrate the datum line, then measure the parallel lines station by station.
  3. Measure transverse sections that link each parallel line to the datum to obtain its start height.
  4. Shift every line by its link result to build unified grid heights.
  5. Compute closure errors at all crossings; re-check outliers on site and handle unresolvable residuals statistically with full documentation.
  6. Evaluate flatness against the agreed reference and report closure distribution, method and uncertainty.

Calculation

Line integration follows straightness: Δh=L·tan(θ″·π/648000), accumulated per segment. The start height of line k comes from its link section and shifts the whole line: zk,i′=zk,i+h0,k. Closure at a crossing is c=zA−zB and all closures should be of similar magnitude; flatness is evaluated on the unified data with the agreed reference.

Illustrative example

Schematic · not measured data
Schematic: parallel lines linked by transverse sections into a grid; closures marked at crossings, data illustrative.

Teaching data, not measured: a 600 mm × 400 mm plate with a 100 mm span and four longitudinal lines of five points. If the datum line ends at +1.9 μm and a linked parallel line starts at +0.7 μm after shifting, its closures are +0.2 μm and −0.1 μm. An example minimum-zone value on the unified data is 3.2 μm; no real part is implied.

Limitations

  • A transverse section linking only one line provides no closure check.
  • Large closures indicate local reading faults; simple averaging hides the problem.
  • Grid results depend on the unification procedure; compare lines only in the common frame.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

Method reference ↗ Method reference ↗ 
STEP BY STEP

Understand the measurement step by step

Principle schematic · not to scale
1 / 6
  1. Top view of the table with 12 stations on a 4 × 3 grid, the central line y=200 highlighted as the baseline.
  2. The reflector base walks the baseline in three spans while the height polyline grows below.
  3. The base moves to the transverse link at x=0 and both parallel lines are lifted to a common starting height.
  4. Lines y=0 and y=400 unfold in turn, each polyline joined to the shared origin.
  5. All heights drop onto the grid and the extreme points flash red.
  6. The containment band tightens and shows 6.6 μm with the pass verdict.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Flatness of a 600 mm × 400 mm cast-iron surface table by grid measurement

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

A 600 mm × 400 mm cast-iron marking-out table is re-checked in the machine shop after being lifted off the grinder and left to settle for 24 h. The autocollimator resolves 0.01″ and the reflector base span is 200 mm, so the station pitch is an integer multiple of the span, giving three longitudinal lines and one transverse link chain.

Setup and preparation

  • Clean the table and lay out the grid: longitudinal lines at x=0/200/400/600 mm and transverse lines at y=0/200/400 mm, 12 stations in total.

  • Take the central longitudinal line y=200 mm as the baseline and measure its three spans first, each exactly 200 mm.

  • Leave the autocollimator untouched and step the reflector base along the parallel lines y=0 and y=400.

  • At x=0 measure the transverse links y=200→0 and y=200→400 to shift the start of each parallel line onto the baseline.

  • Record 21.4 °C; re-measure the start of every line once, with a return-to-zero difference of no more than 0.1″.

Example data and records

  • Baseline y=200 mm, segment 1 (x=0→200 mm): -1.80″

  • Baseline y=200 mm, segment 2 (x=200→400 mm): +3.40″

  • Baseline y=200 mm, segment 3 (x=400→600 mm): +0.80″

  • Parallel line y=0, segment 1 (x=0→200 mm): +3.00″

  • Parallel line y=0, segment 2 (x=200→400 mm): -2.20″

  • Parallel line y=0, segment 3 (x=400→600 mm): +1.60″

  • Parallel line y=400, segment 1 (x=0→200 mm): +2.40″

  • Parallel line y=400, segment 2 (x=200→400 mm): +1.20″

  • Parallel line y=400, segment 3 (x=400→600 mm): -2.80″

  • Transverse link x=0 (y=200→0 mm): -1.00″

  • Transverse link x=0 (y=200→400 mm): +1.40″

  • Closure check at x=600 (y=400→200 mm): +0.90″

  • Closure check at x=600 (y=200→0 mm): +0.20″

Calculation steps

Scale factor k=200×π/648000×1000=0.970 μm per arcsec. The baseline y=200 accumulates +0.00 → -1.75 → +1.55 → +2.33 μm. The transverse links fix the start of each parallel line: +0.97 μm at y=0 and +1.36 μm at y=400. Line y=0 accumulates +0.00 → +2.91 → +0.78 → +2.33 μm locally and +0.97 → +3.88 → +1.75 → +3.30 μm after shifting; line y=400 accumulates +0.00 → +2.33 → +3.49 → +0.78 μm and +1.36 → +3.68 → +4.85 → +2.13 μm after shifting. The 12 grid stations therefore give the height sequence 0.97 → 3.88 → 1.75 → 3.30 → 0.00 → -1.75 → 1.55 → 2.33 → 1.36 → 3.68 → 4.85 → 2.13 μm above the baseline. The highest point +4.85 μm is at (x=400, y=400) and the lowest -1.75 μm at (x=200, y=200), so the flatness is f=4.85−(-1.75)=6.59 μm. A closure link at x=600 rebuilds the A point from C: +2.13 μm plus the two transverse steps gives +3.20 μm against +3.30 μm measured, a difference of 0.10 μm, below 0.5 μm, so the shift is trustworthy.

Interpretation

Grid-method flatness: 6.6 μm. This passes the 10 μm tolerance for a grade 1 table of 600 mm × 400 mm, with 3.4 μm margin.

Verification and pitfalls

  • The closure link at x=600 differs by 0.10 μm; this is the evidence that the parallel lines are shifted correctly, so re-measure the transverse chain above 0.5 μm.

  • The base span must be an integer divisor of the station pitch; both are 200 mm here, so one scale factor covers the whole grid.

  • Re-measure the first and last station of each line and require a return-to-zero difference of at most 0.1″ to catch a lifted base.

  • Keep station numbers and coordinates consistent with the layout drawing, since a swapped coordinate fakes a local bump.

  • Do not change the supports under the table during the run; adjusting a shim invalidates all data already taken.