Inspection plan for theodolite sighting axis versus trunnion axis
For laboratory determination of a theodolite/total station sighting-axis error (collimation c) and trunnion-axis tilt error (i). The autocollimator in collimating mode provides an infinity reference target; face-left/face-right observations separate collimation, and targets at high and low elevations separate trunnion tilt.
Instruments
- Autocollimator in collimating mode with adjustable reticle target
- Stand for high and low target positions
- Forced-centring and levelling base for the instrument
- Temperature equilibrium and reading log tools
Procedure
- Confirm instrument setup, the simulated infinity target and the face-left/face-right observation procedure.
- Fit the adjustable reticle target to the autocollimator to output a collimated beam as the infinity reference; allow full thermal equilibrium.
- Sight the target face-left and read; plunge the telescope (face-right, rotated 180°) and read again.
- Repeat observations at high and low elevation targets to separate trunnion-axis tilt.
- Repeat for three sets; record the scatter and check levelling and temperature state.
- Compute collimation c=(R_FL−R_FR±180°)/2; solve trunnion error i from the high/low elevation difference.
- Deliver the face-left/right reading table, computed c and i, repeatability and environment records.
Calculation
Collimation c=(R_FL−R_FR±180°)/2; trunnion tilt i is solved from the i·tan(h) term in the high/low elevation difference, h the target elevation angle. Reading resolution per instrument specification (0.5″ example, teaching data).
Reporting
- Instrument levelling and thermal equilibrium confirmed
- Scatter of three sets recorded
- Target beam stability checked
Limitations
Does not cover vertical index error, distance-measuring performance or compensator accuracy; results apply only to the environment and setup at measurement. Conformity verdicts follow the verification regulation adopted by the user.
Understand the measurement step by step
- 01
Confirm instrument setup, the simulated infinity target and the face-left/face-right observation procedure.
- 02
Fit the adjustable reticle target to the autocollimator to output a collimated beam as the infinity reference; allow full thermal equilibrium.
- 03
Sight the target face-left and read; plunge the telescope (face-right, rotated 180°) and read again.
- 04
Repeat observations at high and low elevation targets to separate trunnion-axis tilt.
- 05
Repeat for three sets; record the scatter and check levelling and temperature state.
- 06
Compute collimation c=(R_FL−R_FR±180°)/2; solve trunnion error i from the high/low elevation difference.
- 07
Deliver the face-left/right reading table, computed c and i, repeatability and environment records.
- Set up & level · Theodolite centred and levelled on the pier.
- Face-left reading · Collimate the target and read face left.
- Face-right reading · Transit and read face right.
- Compute 2C · Half the face difference gives the collimation error.
- Test i angle · High/low point method yields trunnion inclination.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Theodolite Line of Sight and Trunnion Axis Test · Tutorial Case
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: collimation error 2C and trunnion axis inclination i tests on a theodolite; readings are instructional settings.
Setup and preparation
Set up and carefully level the theodolite on the test pier
Collimate the crosshair of the parallel plate collimator as a near target
Read the horizontal circle on the same target in face left and face right
Determine the collimation error at high and low points
Compute 2C and i as tutorial results
Example data and records
Face-left horizontal reading 0°00′12″
Face-right reading on same target 180°00′06″
High-point collimation error +4.0″, low point +2.0″
Calculation steps
2C = (FL − (FR − 180°))/2 = (12″ − 6″)/2 = +3.0″; trunnion inclination i = (high-point error − low-point error)/2 = (4.0″ − 2.0″)/2 = +1.0″.
Interpretation
2C = +3.0″ and i = +1.0″, both within the teaching limits (2C ≤ ±10″, i ≤ ±15″).
Verification and pitfalls
Bubble shift after levelling within half a division
Same target collimated in both faces
High and low points symmetric about the horizontal line of sight