MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Levelling inspection plan for a hydro turbine stay-ring flange
DOWNLOADABLE MEASUREMENT PLAN

Levelling inspection plan for a hydro turbine stay-ring flange

For installation level and face flatness of a hydro turbine stay-ring flange (Ø6000 mm, example/teaching data). The autocollimator measures multiple radial lines on the large-diameter face, tied to a common datum at the centre; an electronic level cross-checks overall tilt on two orthogonal diameters. After adjustment, re-measure the full ring and keep both versions.

Instruments

Procedure

Calculation

Δh=L·tanθ; with L=250 mm, 1″≈1.212 μm (example/teaching data). Tilt follows from the least-squares plane normal, α≈arctan(Δh/D); the tilt azimuth is the fitted-plane gradient direction.

Reporting

Limitations

Does not cover long-term settlement monitoring of the concrete foundation or flange sealing tests; deformation under unit operating conditions is outside this plan.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Confirm the Ø6000 mm flange (example), the layout of 8 radial lines, support/grouting state and the evaluation method.

  2. 02

    Clean the flange face; lay out nodes along each radial line from the centre bore edge to the outer rim at a 250 mm span.

  3. 03

    Read each line with the autocollimator to 0.1″; cross-check overall tilt with the electronic level on two orthogonal diameters.

  4. 04

    Tie all radial lines at the centre node and integrate via Δh=L·tanθ into the full-ring height distribution.

  5. 05

    Fit a least-squares plane to evaluate face flatness and level tilt; mark the azimuths of high and low points.

  6. 06

    Re-measure the full ring after adjustment and keep both data versions.

  7. 07

    Deliver the ring height map, tilt magnitude and azimuth, adjustment log and re-measurement conclusion.

Principle schematic · not to scale
1 / 5
  1. Flange layout · Face cleaned and division points marked.
  2. Place bridge · The 250 mm bridge set radially.
  3. Read per step · The electronic level reads each tilt.
  4. Convert heights · Tilts convert into micrometre heights.
  5. Level evaluation · Cumulative heights give the flange level.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Hydraulic Turbine Stay Ring Flange Level Inspection · Tutorial Case

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: segmented level survey of a hydraulic turbine stay ring flange; data are instructional settings.

Setup and preparation

  • Clean the flange face and mark the division points

  • Place an electronic level on a 250 mm bridge

  • Step radially, reading the tilt per segment

  • Take two readings per segment and average

  • Cumulate and convert for flange level results

Example data and records

  • Bridge span L=250 mm; segment 1 electronic level reading θ₁=-0.5″

  • Segment 2 electronic level reading θ₂=+1″

  • Segment 3 electronic level reading θ₃=-0.5″

Calculation steps

Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 250×tan(-0.5″)=-0.61 μm; Segment 2: 250×tan(+1″)=+1.21 μm; Segment 3: 250×tan(-0.5″)=-0.61 μm. Cumulative heights: 0→-0.61→+0.60→-0.01 μm; peak-to-valley PV=+0.60−(-0.61)=+1.21 μm.

Interpretation

Tutorial result PV≈1.21 μm, demonstrating micrometre-level level measurement of the stay ring flange.

Verification and pitfalls

  • Bridge centred radially on the flange face

  • Level thermally settled before reading

  • Forward and reverse passes averaged