Glass and technical ceramics

Glass substrates, ceramic guideways, optical windows and sintering platens.

Methods

Procedure

  1. Confirm support
  2. Scan form
  3. Local correction
  4. Re-measure
  5. Record stress and temperature

Thin plates deform under gravity and clamping; measure in the service condition.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗
STEP BY STEP

Understand the measurement step by step

  1. 01

    Confirm support

  2. 02

    Scan form

  3. 03

    Local correction

  4. 04

    Re-measure

  5. 05

    Record stress and temperature

Principle schematic · not to scale
1 / 5
  1. Confirm support
  2. Scan form
  3. Local correction
  4. Re-measure
  5. Record stress and temperature

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Flatness and angle inspection for glass and technical ceramics

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching note: glass substrates and ceramic blanks need high flatness, low roughness and no contact damage; choosing a non-contact method matters more than instrument resolution.

Setup and preparation

  • Split by contact: tactile for coarse checks, non-contact (interferometry, deflectometry, confocal) for finished parts.

  • Handle back-surface reflection on transparent parts with a wedge or temporary coating and say so.

  • State datum and fit for flatness: three-point, least-squares and minimum-zone differ.

  • Temperature and airflow strongly affect interferometry; soak to thermal equilibrium first.

Interpretation

Non-contact methods avoid contact error, but results must be evaluated by the same method before comparison.

Verification and pitfalls

  • Cleanliness decides the result: one particle can fake micrometres of form error.

  • Interferometry has limited range; pre-measure warped parts with deflectometry or a CMM.

Why this method

Errors here are nanometre to micrometre scale and form-dominated; contact measurement adds its own error.

Evaluation boundary

Acceptance uses the drawing flatness, roughness and defect criteria; the test method must match the callout.