Glass and technical ceramics
Glass substrates, ceramic guideways, optical windows and sintering platens.
Methods
- Large-plate flatness
- Edge straightness
- Mounting-face parallelism
- Setter-plate flatness
Procedure
- Confirm support
- Scan form
- Local correction
- Re-measure
- Record stress and temperature
Thin plates deform under gravity and clamping; measure in the service condition.
Typical measurement scenarios in this industry
Each scenario gives the object, tolerance range and method, ready to take to the selector.
Glass substrate flatness
1.5×1.8 m substrates; evaluate in the service support condition.
General-purpose electronic autocollimators↗Ceramic guideway straightness
Travel 0.5–2 m, typically 3–5 μm/m; control clamping force.
General-purpose electronic autocollimators↗Optical window parallelism
Windows 50–200 mm, parallelism ≤ 10″; use front and rear surface reflections.
General-purpose electronic autocollimators↗Understand the measurement step by step
- 01
Confirm support
- 02
Scan form
- 03
Local correction
- 04
Re-measure
- 05
Record stress and temperature
- Confirm support
- Scan form
- Local correction
- Re-measure
- Record stress and temperature
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Flatness and angle inspection for glass and technical ceramics
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching note: glass substrates and ceramic blanks need high flatness, low roughness and no contact damage; choosing a non-contact method matters more than instrument resolution.
Setup and preparation
Split by contact: tactile for coarse checks, non-contact (interferometry, deflectometry, confocal) for finished parts.
Handle back-surface reflection on transparent parts with a wedge or temporary coating and say so.
State datum and fit for flatness: three-point, least-squares and minimum-zone differ.
Temperature and airflow strongly affect interferometry; soak to thermal equilibrium first.
Interpretation
Non-contact methods avoid contact error, but results must be evaluated by the same method before comparison.
Verification and pitfalls
Cleanliness decides the result: one particle can fake micrometres of form error.
Interferometry has limited range; pre-measure warped parts with deflectometry or a CMM.
Why this method
Errors here are nanometre to micrometre scale and form-dominated; contact measurement adds its own error.
Evaluation boundary
Acceptance uses the drawing flatness, roughness and defect criteria; the test method must match the callout.