MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Power generation equipment
APPLICATION GUIDE

Power generation equipment

Steam turbines, generators, wind main shafts, hydro units and transformer foundations.

Methods

Procedure

  1. Foundation acceptance
  2. Bearing housing alignment
  3. Shaft train alignment
  4. Coupling alignment
  5. Re-check after run-in

Cold alignment must be corrected by the thermal growth curve; it is not the running condition.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗
STEP BY STEP

Understand the measurement step by step

  1. 01

    Foundation acceptance

  2. 02

    Bearing housing alignment

  3. 03

    Shaft train alignment

  4. 04

    Coupling alignment

  5. 05

    Re-check after run-in

Principle schematic · not to scale
1 / 5
  1. Foundation acceptance
  2. Bearing housing alignment
  3. Shaft train alignment
  4. Coupling alignment
  5. Re-check after run-in

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Large-scale geometric inspection for power equipment

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching note: turbines, generators, transformers and wind components are large, warm up in service and are expensive to dismantle; the plan must be field-capable and traceable.

Setup and preparation

  • Separate cold and hot states: hot for diagnosis, cold for acceptance; limits are not interchangeable.

  • Align long spans with an autocollimator plus turning mirror, or fit a datum axis from laser-tracker points.

  • Log support and foundation loads with the temperature field so thermal deflection is not read as geometry error.

  • Re-measure key items within the outage window and keep before/after data at identical points.

Interpretation

Before/after data at identical points say more about an adjustment than any single measurement.

Verification and pitfalls

  • Check air turbulence on long paths; shorten the path or use a tube.

  • Record the number and position of turning mirrors or the result is not reproducible.

Why this method

Tolerances are often given per metre, so the span must be recorded or the limit cannot be scaled.

Evaluation boundary

Acceptance follows the equipment agreement and maintenance rules; hot data serve trending only.