MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Robotics & Automated Assembly
APPLICATION GUIDE

Robotics & Automated Assembly

Robot linear axes, calibration fixtures and end-effector optical references

Methods

Procedure

  1. Define base coordinates
  2. Check fixtures
  3. Measure positions
  4. Adjust the external axis
  5. Repeat positioning checks

Angular measurements do not replace six-degree-of-freedom verification across the robot workspace.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗
InspectionRepeatability & Re-setup Verification

Robot joint angular repeatability

Thirty round trips to one commanded pose give the angular spread. Compare with the rated repeatability to flag gearbox wear.

Zhongji high-speed dynamic autocollimators↗
AssemblyStraightness

Seventh-axis track straightness and parallelism

Tracks of 5–20 m: each rail must be straight and the pair parallel. Do single-rail straightness first, then lateral offset against one datum rail.

Machine-tool autocollimator series↗
AssemblySmall Angles & Indexing Error

End-effector mounting attitude

The angle between flange and tooling datum sets grasp attitude. Attach a flat mirror to the flange and read the two-axis deviation directly.

Zhongji automatic measurement series↗
InspectionStage Pitch & Yaw

AGV and mobile platform travel attitude

Fixed mirrors along the route give the yaw angle as the vehicle passes, verifying navigation repeatability and path adherence.

General-purpose electronic autocollimators↗
AssemblyStage Pitch & Yaw

Robot base levelling and re-check

Six-axis robot base, typically 0.02–0.05 mm/m. Read pitch and roll together and re-check under load for the installation record.

General-purpose electronic autocollimators↗
CalibrationSmall Angles & Indexing Error

Robot joint zero-position calibration aid

When restoring joint zero, verify the mechanical zero angle with a goniometer or autocollimator and target mirror; tolerance is usually within ±30″.

Goniometers↗
CalibrationOptical Alignment

Robot TCP calibration

Four-pose or multi-point calibration, residual ≤ 0.1 mm; redo after tool change.

General-purpose electronic autocollimators↗
AssemblyStraightness

Robot seventh-axis rail straightness

Travel 3–10 m, typically 0.05 mm/m; transfer the datum in stages.

General-purpose electronic autocollimators↗

Recommended instruments

STEP BY STEP

Understand the measurement step by step

  1. 01

    Define base coordinates

  2. 02

    Check fixtures

  3. 03

    Measure positions

  4. 04

    Adjust the external axis

  5. 05

    Repeat positioning checks

x̄12345Repeated readings scatter about the mean; not a drift curveReading numberPrinciple schematic · not to scale
1 / 4
  1. Fix arrival conditions · Fix the target station and position reference, define the positive offset and prescribe the same approach direction, starting point and motion condition for every arrival.
  2. Repeat position readings · Keep load and mounting unchanged and record five offsets after the prescribed settling time. These positions are not direct autocollimator angular readings.
  3. Separate mean and spread · Calculate mean offset, sample standard deviation and maximum-minus-minimum separately, retaining their different statistical meanings.
  4. Extend directions and stations · Add independent groups for the opposite approach and other travel positions, then investigate guideway straightness, pitch/yaw and end-effector geometry.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Automation external linear axis: repeat arrivals at one station

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project. Five unidirectional arrivals at one fixed station of a robot external linear axis are recorded using an independent position-measurement system. The example separates mean offset from spread and does not label a single-axis, single-station result as six-degree-of-freedom robot accuracy.

Setup and preparation

  • Fix the target station and position reference, define the positive offset and prescribe the same approach direction, starting point and motion condition for every arrival.

  • Keep load and mounting unchanged and record five offsets after the prescribed settling time. These positions are not direct autocollimator angular readings.

  • Calculate mean offset, sample standard deviation and maximum-minus-minimum separately, retaining their different statistical meanings.

  • Add independent groups for the opposite approach and other travel positions, then investigate guideway straightness, pitch/yaw and end-effector geometry.

Example data and records

  • Synthetic unidirectional position offsets: 20, 22, 19, 21, 18 μm.

  • One load and station; uncertainty of the target reference is not supplied.

  • Keep approach direction fixed within a group instead of mixing reversal effects into dispersion.

Calculation steps

Mean offset x̄=(20+22+19+21+18)/5=20 μm; s=sqrt[(0²+2²+(−1)²+1²+(−2)²)/(5−1)]=1.581139 μm; range=22−18=4 μm.

Interpretation

This group has a +20 μm mean offset, sample standard deviation approximately 1.581139 μm and range 4 μm. These indicators differ and do not replace overall positioning or pose-performance definitions in robot standards.

Verification and pitfalls

  • Use an external position system with suitable traceability and uncertainty.

  • Report opposite approach directions separately rather than interpreting their difference as random spread.

  • Angular-axis effects at the end effector depend on offset, pose and load; do not extrapolate from a single station.