Principle
Angular error describes axis tilt; positional error describes lateral translation. Each needs an observable quantity.
Preparation
Define the relationship between mechanical and optical datums. Select appropriate mirrors, targets and fixtures and verify the line of sight.
Workflow diagram
Procedure
- Define the target axis, reference locations and allowed angular and positional deviations.
- Establish a stable optical reference and verify its relationship to the mechanical datum.
- Measure direction first, then measure lateral offsets using suitable alignment targets or displacement methods.
- Adjust the datum component before dependent components; do not judge an entire axis from one coincident point.
- Verify at several axial locations and record changes after tightening or remounting.
Calculation
At two axial stations, offsets d₁,d₂ separated by L give θ≈(d₂−d₁)/L for small angles. One section cannot determine the complete axis direction.
Illustrative example
Illustration: a 10 μm offset difference over 1 m gives about 10 μrad or 2.06″; overall decentring remains separate.
Limitations
- A correct reflected direction does not by itself demonstrate mechanical coaxiality.
- Axis position and angle are distinct quantities.
- Fixture eccentricity and locking distortion require separate checks.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.