MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Flatness
MEASUREMENT METHOD

Flatness

Evaluate the form of a table, platform or mounting surface. Select a method appropriate to its size and finish.

Principle

Slope methods integrate connected lines; direct-height methods measure coordinates in a shared reference.

Preparation

Specify the measurement area, grid, support condition and evaluation method. Separate slope reconstruction from direct coordinate measurement.

Workflow diagram

01Design a grid or closed measurement network with share02Stabilize the supports and temperature03Integrate slope readings along each line04Bring all lines into a common height reference and ins05Report the map

Procedure

  1. Design a grid or closed measurement network with shared nodes and check paths.
  2. Stabilize the supports and temperature, clean the surface and define coordinates.
  3. Integrate slope readings along each line, or record direct point heights with an appropriate system.
  4. Bring all lines into a common height reference and inspect junction and closure discrepancies.
  5. Report the map, sampling layout, fitting method and limitations between measured points.

Calculation

After fitting z=ax+by+c, compute rᵢ=zᵢ−(axᵢ+byᵢ+c) and PV=max(rᵢ)−min(rᵢ). This is residual PV about that plane; minimum-zone evaluation is separate.

Illustrative example

Schematic · not measured data
Schematic: grid, shared nodes and closure checks; example heights do not represent a tested table.

Illustration: fitted residuals of +2 and −1 μm give a 3 μm PV about that plane, not automatically minimum-zone flatness.

Limitations

  • Do not combine profiles that have each been independently reset to zero.
  • Peak-to-valley residuals about a least-squares plane are not the minimum-zone flatness result.
  • A sparse grid may miss local defects.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

Method reference ↗ Method reference ↗ 
STEP BY STEP

Understand the measurement step by step

Principle schematic · not to scale
1 / 4
  1. Define grid · Fix the support condition and define nine points at x and y positions 0, 100 and 200 mm, all sharing one height datum.
  2. Reconcile heights · Enter the illustrative heights by row and identify them as height coordinates after datum reconciliation, rather than raw angles.
  3. Fit plane · Fit z=ax+by+c; use symmetry to verify that a and b are zero, then compute residuals at every point.
  4. Check coverage · Draw the nine-point map and central rise; identify unsampled areas and plan denser sampling around the centre.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

A nine-point plane-fitting example

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: fit a plane to a 3×3 platform grid and show how independently zeroing lines can conceal a central rise. The heights are assumed inputs, not direct autocollimator readings.

Setup and preparation

  • Fix the support condition and define nine points at x and y positions 0, 100 and 200 mm, all sharing one height datum.

  • Enter the illustrative heights by row and identify them as height coordinates after datum reconciliation, rather than raw angles.

  • Fit z=ax+by+c; use symmetry to verify that a and b are zero, then compute residuals at every point.

  • Draw the nine-point map and central rise; identify unsampled areas and plan denser sampling around the centre.

Example data and records

  • Rows at y=0, 100 and 200 mm: [0,1,0], [1,4,1] and [0,1,0] μm.

  • Mean height: 8/9=0.888889 μm.

  • Fitted plane: z=0.888889 μm; residuals are −0.888889 at corners, +0.111111 at edge centres and +3.111111 μm at the centre.

Calculation steps

The least-squares slopes are a=b=0. Residual peak-to-valley=max(z−zfit)−min(z−zfit)=3.111111−(−0.888889)=4 μm.

Interpretation

The illustrative grid has a 4 μm residual range relative to its least-squares plane. No minimum-zone calculation or statement about unsampled regions or conformance is implied.

Verification and pitfalls

  • All points need a common datum; separately zeroed lines cannot simply be stitched together.

  • Record support positions, loading and sampling density, and remeasure after support changes.

  • For an angular method, complete integration, common-node reconciliation and closure checks before using a height grid.