NC machine geometric acceptance (ISO 230-1)
For new-machine acceptance, post-relocation verification or overhaul. Measure each item with agreed lines, travel and evaluation.
Instruments
- Select autocollimator or interferometer by travel and tolerance
- Bridge, span gauge, pentaprism and reference square
- Temperature, pressure and vibration logging
Procedure
- Agree the standard, item list, tolerances and evaluation method in a signed measurement plan.
- Warm up the machine and record temperature, foundation and air supply.
- Measure straightness, squareness, parallelism and spindle items per ISO 230-1 with one datum and sign convention.
- For out-of-tolerance items, separate installation, thermal and geometric causes before adjusting.
- Re-measure the same stations and report before/after with uncertainty.
Calculation
Convert angles by Δh = L·tanθ. Combine axes on a common datum; do not subtract independently zeroed profiles.
Reporting
- Stations and spans recorded
- Bidirectional repeatability consistent
- Environment within limits
- Out-of-tolerance item localised
Limitations
Geometric acceptance does not replace positioning, circular or cutting tests. Contract tolerances govern.
Understand the measurement step by step
- 01
Agree the standard, item list, tolerances and evaluation method in a signed measurement plan.
- 02
Warm up the machine and record temperature, foundation and air supply.
- 03
Measure straightness, squareness, parallelism and spindle items per ISO 230-1 with one datum and sign convention.
- 04
For out-of-tolerance items, separate installation, thermal and geometric causes before adjusting.
- 05
Re-measure the same stations and report before/after with uncertainty.
- Step 1 · Agree the standard, item list, tolerances and evaluation method in a signed measurement plan.
- Step 2 · Warm up the machine and record temperature, foundation and air supply.
- Step 3 · Measure straightness, squareness, parallelism and spindle items per ISO 230-1 with one datum and sign convention.
- Step 4 · For out-of-tolerance items, separate installation, thermal and geometric causes before adjusting.
- Step 5 · Re-measure the same stations and report before/after with uncertainty.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Worked single-axis straightness example for an 800 mm travel
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching example, not an acceptance record: five 200 mm bays over 800 mm, angles read by autocollimator and integrated into a profile before evaluating straightness. Synthetic data.
Setup and preparation
Agree the standard, item list, tolerances and evaluation method in a signed measurement plan.
Warm up the machine and record temperature, foundation and air supply.
Measure straightness, squareness, parallelism and spindle items per ISO 230-1 with one datum and sign convention.
For out-of-tolerance items, separate installation, thermal and geometric causes before adjusting.
Example data and records
Bay angles: +1″, +0″, -1″, -1″, +0″ at 0, 200, 400, 600, 800 mm.
Height increments: 0.97, 0, −0.97, −0.97, 0 µm.
Accumulated profile in µm: 0.97, 0.97, 0, −0.97, −0.97 µm.
Calculation steps
Δh = 200×1000×tan(1π/648000) = 0.97 µm; the profile range is 1.939 µm. Using the end-point line as datum gives a different number and must be stated.
Interpretation
Straightness is about 1.939 µm with a convex middle. If the drawing states a per-metre tolerance, scale it to 800 mm before comparing.
Verification and pitfalls
Keep one sign convention; re-zeroing mid-travel breaks the integration.
A reverse run exposes contact and drift; never average two inconsistent directions.
Straightness applies to one line, never to a whole surface.