Home / Linear axis positioning and repeatability (ISO 230-2)
DOWNLOADABLE MEASUREMENT PLAN

Linear axis positioning and repeatability (ISO 230-2)

Positioning, repeatability and reversal error of NC axes, precision stages and linear modules for acceptance, compensation and diagnosis.

Instruments

Procedure

Calculation

Deviation is command minus mean measured position; repeatability follows the standard interval; reversal is the difference between approach directions.

Reporting

Limitations

Positioning accuracy is not machining accuracy; screw growth and servo gain vary with speed and load.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Define target count, distribution, repeat count and feed rate.

  2. 02

    Set up the beam, align to the axis and check return over full travel.

  3. 03

    Approach each target from both directions in the standard sequence.

  4. 04

    Compute positioning deviation, repeatability and reversal error; look for periodic terms.

  5. 05

    If compensating, keep raw data and re-measure with the same program.

x̄12345Repeated readings scatter about the mean; not a drift curveReading numberPrinciple schematic · not to scale
1 / 5
  1. Step 1 · Define target count, distribution, repeat count and feed rate.
  2. Step 2 · Set up the beam, align to the axis and check return over full travel.
  3. Step 3 · Approach each target from both directions in the standard sequence.
  4. Step 4 · Compute positioning deviation, repeatability and reversal error; look for periodic terms.
  5. Step 5 · If compensating, keep raw data and re-measure with the same program.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Worked bidirectional positioning example over 500 mm

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching example: five targets approached from both directions; unidirectional mean deviation, repeatability and reversal are derived. One run per direction is shown; the standard requires more.

Setup and preparation

  • Define target count, distribution, repeat count and feed rate.

  • Set up the beam, align to the axis and check return over full travel.

  • Approach each target from both directions in the standard sequence.

  • Compute positioning deviation, repeatability and reversal error; look for periodic terms.

Example data and records

  • Targets in mm: 0, 125, 250, 375, 500.

  • Forward deviations in µm: +0, -2, +4, -3, +2.

  • Reverse deviations in µm: +3, +3, +9, +2, +6.

Calculation steps

Forward mean 0.2 µm, reverse mean 4.6 µm; forward range 7 µm; reversal B = 4.4 µm. A formal report needs the number of runs the standard requires.

Interpretation

Reversal of 4.4 µm exceeds the unidirectional range, pointing at backlash or preload rather than random noise.

Verification and pitfalls

  • Check cosine error; a misaligned beam scales all readings.

  • Log compensation and material temperature; never mix compensated and raw data.

  • Accuracy, repeatability and reversal are three separate figures.