MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Robot cell installation and calibration
DOWNLOADABLE MEASUREMENT PLAN

Robot cell installation and calibration

Base level, tool frame and relative pose of external axes or vision systems.

Instruments

Procedure

Calculation

Base tilt enters the tool pose directly; check residual distribution, not only the mean.

Reporting

Limitations

Temperature and payload affect results; re-calibrate after tool change or collision.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Confirm mounting face, foot preload and working envelope.

  2. 02

    Level the base in both pitch and roll.

  3. 03

    Establish robot and workpiece frames with a tracker or spheres.

  4. 04

    Calibrate TCP and external-axis relations; check residuals.

  5. 05

    Re-measure several poses and report residuals and compensation.

d₁d₂θx_midLSection 1Section 2Two sections separate position offset from angular tiltPrinciple schematic · not to scale
1 / 5
  1. Step 1 · Confirm mounting face, foot preload and working envelope.
  2. Step 2 · Level the base in both pitch and roll.
  3. Step 3 · Establish robot and workpiece frames with a tracker or spheres.
  4. Step 4 · Calibrate TCP and external-axis relations; check residuals.
  5. Step 5 · Re-measure several poses and report residuals and compensation.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Worked robot base tilt and calibration residual example

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching example: base tilt 30″ over a 1500 mm reach, plus calibration residuals at six poses to contrast mean and maximum error.

Setup and preparation

  • Confirm mounting face, foot preload and working envelope.

  • Level the base in both pitch and roll.

  • Establish robot and workpiece frames with a tracker or spheres.

  • Calibrate TCP and external-axis relations; check residuals.

Example data and records

  • Base tilt 30″ gives 218 µm at the working radius.

  • Residuals at six poses in mm: 0.04, 0.07, 0.05, 0.18, 0.06, 0.09.

  • The largest residual occurs at an extended pose near the workspace edge.

Calculation steps

Offset = R·tanθ = 218 µm. Residual mean is 0.082 mm against a maximum of 0.18 mm; the mean hides the edge poses.

Interpretation

A base tilt of 218 µm grows downstream; level the base before calibrating or the calibration absorbs geometric error.

Verification and pitfalls

  • Inspect residuals per pose, not only the mean.

  • Temperature and payload change robot geometry; log the state during calibration.

  • Confirm anchor and floor stiffness; looseness turns error into noise.