Telescope and multi-axis optical alignment
Alignment of primary and secondary mirrors, sensor boresights and laser transmit/receive paths.
Instruments
- Autocollimator and collimator
- Large flat or autocollimation target
- Precision mounts and thermal stability
Procedure
- Define the main axis, mechanical datum and pointing budget.
- Establish an infinity target and check the primary return.
- Adjust secondary, focal plane and detector, logging each change.
- Separate offset from tilt by two sections or image rotation.
- Re-measure after thermal stabilisation and report pointing error.
Calculation
Secondary tilt θ shifts focus by Δ = 2f·tanθ for a two-reflection system; offset shifts the image and adds coma.
Reporting
- Main axis defined
- Adjustments tied to readings
- Re-measured when stable
- Offset and tilt separated
Limitations
Laboratory results need star or long-range verification; turbulence limits field accuracy.
Understand the measurement step by step
- 01
Define the main axis, mechanical datum and pointing budget.
- 02
Establish an infinity target and check the primary return.
- 03
Adjust secondary, focal plane and detector, logging each change.
- 04
Separate offset from tilt by two sections or image rotation.
- 05
Re-measure after thermal stabilisation and report pointing error.
- Step 1 · Define the main axis, mechanical datum and pointing budget.
- Step 2 · Establish an infinity target and check the primary return.
- Step 3 · Adjust secondary, focal plane and detector, logging each change.
- Step 4 · Separate offset from tilt by two sections or image rotation.
- Step 5 · Re-measure after thermal stabilisation and report pointing error.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Worked secondary-mirror tilt and focal shift example at f = 1200 mm
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching example: a 1200 mm reflector with the secondary tilted 5″; the focal-plane shift follows from the double reflection, and eccentricity is distinguished from tilt.
Setup and preparation
Define the main axis, mechanical datum and pointing budget.
Establish an infinity target and check the primary return.
Adjust secondary, focal plane and detector, logging each change.
Separate offset from tilt by two sections or image rotation.
Example data and records
Secondary tilt 5″ measured by autocollimator, repeatability 0.1″.
Focal shift Δ = 2f·tanθ ≈ 58.2 µm.
Star test: tilt shows coma, decentre shows image shift.
Calculation steps
Δ = 2 × 1200 × tan(5π/648000) × 1000 = 58.2 µm. The factor 2 comes from the single fold of a reflective surface; a refractor uses 1.
Interpretation
A shift of 58.2 µm may pass on a short-focus camera but not with small pixels; converge on both the star test and the autocollimator reading.
Verification and pitfalls
Never touch optical surfaces with fingers or ordinary tissue.
Re-check axis versus mechanical datum; do not optimise one field only.
Record temperature and star images before and after.