Wind Power Equipment
Yaw and pitch bearing housings, main-shaft and gearbox mounting faces, nacelle base frames, tower flanges, blade moulds and inspection fixtures
Methods
- Flatness of yaw bearing mounting faces
- Main-shaft to gearbox alignment
- Straightness of nacelle base guideways
- Parallelism of tower flange faces
- Datum angles of blade moulds
Procedure
- Establish component datums
- Measure mounting-face flatness
- Align shaft axes
- Adjust shims
- Verify and record
Geometric checks do not replace load and fatigue tests, vibration and power-curve verification, nor whole-turbine acceptance after site erection.
Recommended instruments


Dual-axis electronic autocollimator accuracy 1″ maximum measuring distance 10m

Dual-axis electronic autocollimator accuracy 1″ maximum measuring distance 20m
Understand the measurement step by step
- 01
Establish component datums
- 02
Measure mounting-face flatness
- 03
Align shaft axes
- 04
Adjust shims
- 05
Verify and record
- Mark nodes · Mark five nodes along a longitudinal line on the mounting face at 100 mm spacing (total 400 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 100 mm sampling step.
- Align optics · Set up the autocollimator using the upper tower flange face for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
- Integrate · Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
- Reverse run · Repeat the run in reverse over the same nodes, compare the two residual profiles and keep the raw angles together with before-and-after adjustment records.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Teaching example: levelness of a yaw bearing mounting face
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: a 400 mm section of the yaw bearing mounting face shows how interval angles from autocollimation are reconstructed into a height profile. The values are teaching assumptions and are not acceptance limits for wind power.
Setup and preparation
Mark five nodes along a longitudinal line on the mounting face at 100 mm spacing (total 400 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 100 mm sampling step.
Set up the autocollimator using the upper tower flange face for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
Read and retain the raw angle of every interval rather than a smoothed display value, and log ambient temperature, time of measurement, and conditions such as uneven solar heating and through-draft inside the nacelle.
Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
Example data and records
Interval angles: 1.0″, 1.5″, −0.8″, 0.5″.
Span and sampling step: 100 mm, four intervals; the first node is defined as 0 μm.
Cumulative node heights: 0.000, 0.485, 1.212, 0.824, 1.067 μm; residuals against the endpoint line: 0.000, 0.218, 0.679, 0.024, 0.000 μm.
Calculation steps
For each interval Δh = 100×1000×tan(θ·π/648000) μm. With the four angles this gives Δh ≈ 0.485, 0.727, −0.388, 0.242 μm; cumulative heights are 0.000, 0.485, 1.212, 0.824, 1.067 μm, residuals after removing the endpoint line are 0.000, 0.218, 0.679, 0.024, 0.000 μm and the peak-to-valley value is 0.679 μm.
Interpretation
For the given sampling and endpoint reference the residual peak-to-valley of a longitudinal line on the mounting face is about 0.679 μm. It describes only the static geometry of this 400 mm line and is not an acceptance conclusion for wind power.
Verification and pitfalls
Confirm that the reflector span matches the actual sampling step; the simple integration model cannot be applied when they differ.
A reverse run shows repeatability only and does not remove contact deformation or thermal drift of the yaw bearing mounting face; uneven solar heating and through-draft inside the nacelle must be assessed separately.
Any report must state the reference, evaluation algorithm, tolerance and measurement uncertainty.