Home / Nuclear Power Equipment
APPLICATION GUIDE

Nuclear Power Equipment

Reactor pressure vessel supports and shims, main coolant pump and piping supports, control rod drive guide columns, steam generator tube sheets, reactor internals

Methods

Procedure

  1. Confirm datums and cleanliness
  2. Measure support faces
  3. Measure component in place
  4. Adjust shims
  5. Independent re-check

Geometric inspection does not replace non-destructive testing, pressure tests, seismic and irradiation qualification, and is not a nuclear-safety compliance statement.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Confirm datums and cleanliness

  2. 02

    Measure support faces

  3. 03

    Measure component in place

  4. 04

    Adjust shims

  5. 05

    Independent re-check

Principle schematic · not to scale
1 / 4
  1. Mark nodes · Mark five nodes along a line on the shim top face at 50 mm spacing (total 200 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 50 mm sampling step.
  2. Align optics · Set up the autocollimator using the machined face of the embedded plate for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
  3. Integrate · Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
  4. Reverse run · Repeat the run in reverse over the same nodes, compare the two residual profiles and keep the raw angles together with before-and-after adjustment records.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Teaching example: levelness of a reactor support shim

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: a 200 mm section of a reactor support shim shows how interval angles from autocollimation are reconstructed into a height profile. The values are teaching assumptions and are not acceptance limits for nuclear power.

Setup and preparation

  • Mark five nodes along a line on the shim top face at 50 mm spacing (total 200 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 50 mm sampling step.

  • Set up the autocollimator using the machined face of the embedded plate for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.

  • Read and retain the raw angle of every interval rather than a smoothed display value, and log ambient temperature, time of measurement, and conditions such as air movement and lighting heat in a confined space.

  • Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.

Example data and records

  • Interval angles: 0.6″, −0.4″, 0.9″, 0.3″.

  • Span and sampling step: 50 mm, four intervals; the first node is defined as 0 μm.

  • Cumulative node heights: 0.000, 0.145, 0.048, 0.267, 0.339 μm; residuals against the endpoint line: 0.000, 0.061, −0.121, 0.012, 0.000 μm.

Calculation steps

For each interval Δh = 50×1000×tan(θ·π/648000) μm. With the four angles this gives Δh ≈ 0.145, −0.097, 0.218, 0.073 μm; cumulative heights are 0.000, 0.145, 0.048, 0.267, 0.339 μm, residuals after removing the endpoint line are 0.000, 0.061, −0.121, 0.012, 0.000 μm and the peak-to-valley value is 0.182 μm.

Interpretation

For the given sampling and endpoint reference the residual peak-to-valley of a line on the shim top face is about 0.182 μm. It describes only the static geometry of this 200 mm line and is not an acceptance conclusion for nuclear power.

Verification and pitfalls

  • Confirm that the reflector span matches the actual sampling step; the simple integration model cannot be applied when they differ.

  • A reverse run shows repeatability only and does not remove contact deformation or thermal drift of a reactor support shim; air movement and lighting heat in a confined space must be assessed separately.

  • Any report must state the reference, evaluation algorithm, tolerance and measurement uncertainty.