MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Plastics and Rubber Machinery
APPLICATION GUIDE

Plastics and Rubber Machinery

Injection-moulding platens, tie bars, screws and barrels, extruder frames, mould locating rings

Methods

Procedure

  1. Level the frame
  2. Check platen parallelism
  3. Measure tie bars
  4. Re-measure when hot
  5. Adjust and record

Geometric checks do not replace clamping-force tests, trial moulding and part inspection, or plasticising and energy-performance validation.

Recommended instruments

STEP BY STEP

Understand the measurement step by step

  1. 01

    Level the frame

  2. 02

    Check platen parallelism

  3. 03

    Measure tie bars

  4. 04

    Re-measure when hot

  5. 05

    Adjust and record

Principle schematic · not to scale
1 / 4
  1. Mark nodes · Mark five nodes along a line on the platen mounting face at 50 mm spacing (total 200 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 50 mm sampling step.
  2. Align optics · Set up the autocollimator using the upper face of the frame guideway for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
  3. Integrate · Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
  4. Reverse run · Repeat the run in reverse over the same nodes, compare the two residual profiles and keep the raw angles together with before-and-after adjustment records.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Teaching example: parallelism of an injection-moulding platen

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: a 200 mm section of an injection-moulding fixed platen shows how interval angles from autocollimation are reconstructed into a height profile. The values are teaching assumptions and are not acceptance limits for plastics and rubber machinery.

Setup and preparation

  • Mark five nodes along a line on the platen mounting face at 50 mm spacing (total 200 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 50 mm sampling step.

  • Set up the autocollimator using the upper face of the frame guideway for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.

  • Read and retain the raw angle of every interval rather than a smoothed display value, and log ambient temperature, time of measurement, and conditions such as barrel radiation and clamping force.

  • Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.

Example data and records

  • Interval angles: 0.9″, 1.3″, −0.6″, 0.2″.

  • Span and sampling step: 50 mm, four intervals; the first node is defined as 0 μm.

  • Cumulative node heights: 0.000, 0.218, 0.533, 0.388, 0.436 μm; residuals against the endpoint line: 0.000, 0.109, 0.315, 0.061, 0.000 μm.

Calculation steps

For each interval Δh = 50×1000×tan(θ·π/648000) μm. With the four angles this gives Δh ≈ 0.218, 0.315, −0.145, 0.048 μm; cumulative heights are 0.000, 0.218, 0.533, 0.388, 0.436 μm, residuals after removing the endpoint line are 0.000, 0.109, 0.315, 0.061, 0.000 μm and the peak-to-valley value is 0.315 μm.

Interpretation

For the given sampling and endpoint reference the residual peak-to-valley of a line on the platen mounting face is about 0.315 μm. It describes only the static geometry of this 200 mm line and is not an acceptance conclusion for plastics and rubber machinery.

Verification and pitfalls

  • Confirm that the reflector span matches the actual sampling step; the simple integration model cannot be applied when they differ.

  • A reverse run shows repeatability only and does not remove contact deformation or thermal drift of an injection-moulding fixed platen; barrel radiation and clamping force must be assessed separately.

  • Any report must state the reference, evaluation algorithm, tolerance and measurement uncertainty.