MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Datum Transfer & Closure Checks
MEASUREMENT METHOD

Datum Transfer & Closure Checks

Connect local measurements across long ranges or multiple lines and check reference-transfer consistency.

Principle

Common nodes constrain local coordinate systems; independent closure paths check the connection model and drift.

Preparation

Define common nodes, overlaps and closed routes; record stand moves, mirror orientation and coordinates.

Workflow diagram

01Divide the range and define overlaps and independent c02Measure common references and retain unadjusted raw da03Move the station or optical path and remeasure common 04Evaluate overlap and closure discrepancies before cons05Retain before/after data

Procedure

  1. Divide the range and define overlaps and independent check paths.
  2. Measure common references and retain unadjusted raw data.
  3. Move the station or optical path and remeasure common nodes.
  4. Evaluate overlap and closure discrepancies before constrained stitching.
  5. Retain before/after data, the connection model and transfer uncertainty.

Calculation

For a consistently signed closed height route, c=ΣΔhᵢ. For angle closure, subtract the nominal total angle appropriate to the geometry. Distribute corrections only under a justified model.

Illustrative example

Schematic · not measured data
Principle and workflow schematic. Numbers are worked examples, not customer or instrument test results.

Illustration: increments +2, +3, −1 and −3 μm give +1 μm closure. Investigate its cause rather than declaring all points acceptable.

Limitations

  • Do not force closure by arbitrary shifts of individual segments.
  • Small closure does not prove absence of all systematic errors.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

Method reference ↗ Method reference ↗ Method reference ↗ 
STEP BY STEP

Understand the measurement step by step

ABCDΔh_ABΔh_BCΔh_CDΔh_DAc = ΣΔhA → B → C → D → APrinciple schematic · not to scale
1 / 4
  1. Define closed path · Define the loop A→B→C→D→A and a common sign convention; identify the shared nodes used by each leg.
  2. Record each leg · Enter the illustrative differences without altering the raw record and animate cumulative height along the path.
  3. Calculate raw misclosure · At A, calculate misclosure and inspect signs, transcription, common points and measurement conditions before applying compensation.
  4. Resolve with evidence · Only as an equal-weight constraint example, assign −0.25 μm to each leg; real adjustment requires uncertainty, correlations and validation, with corrections retained.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Checking a datum transfer around a four-leg loop

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: signed height differences return to the start to test closure. Zero closure is a geometric constraint, not permission to average away every discrepancy.

Setup and preparation

  • Define the loop A→B→C→D→A and a common sign convention; identify the shared nodes used by each leg.

  • Enter the illustrative differences without altering the raw record and animate cumulative height along the path.

  • At A, calculate misclosure and inspect signs, transcription, common points and measurement conditions before applying compensation.

  • Only as an equal-weight constraint example, assign −0.25 μm to each leg; real adjustment requires uncertainty, correlations and validation, with corrections retained.

Example data and records

  • Raw leg differences: [+2,+3,−1,−3] μm.

  • Cumulative heights: [0,2,5,4,1] μm; the endpoint has not returned to zero.

  • With assumed equal weights and a valid closure model, adjusted illustrative differences are [1.75,2.75,−1.25,−3.25] μm.

Calculation steps

Raw misclosure c=2+3−1−3=+1 μm. The illustrative equal-weight correction is vi=−c/4=−0.25 μm; the adjusted differences sum to zero.

Interpretation

The +1 μm misclosure triggers investigation. An adjusted sum of zero does not prove accuracy or conformance; report raw misclosure, corrections and their justification together.

Verification and pitfalls

  • Confirm return to the same physical datum under consistent support and thermal conditions.

  • Investigate blunders and systematic effects before constrained adjustment.

  • Unequal or correlated uncertainties do not support simple equal allocation.