MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Pitch, Yaw and Roll of a Moving Stage
MEASUREMENT METHOD

Pitch, Yaw and Roll of a Moving Stage

Measure the three angular errors of a moving stage along its travel: pitch about a horizontal axis normal to travel, yaw about the vertical axis, and roll about the travel axis. Together they define the attitude error affecting machining and measuring accuracy. It suits acceptance testing and error-compensation modelling of machine-tool and CMM axes.

Principle

A plane mirror fixed to the stage is read in two orthogonal axes by a two-axis autocollimator. With the optical axis along the travel, the two readings map to pitch and yaw only insofar as the mirror normal allows: rotation of a plane mirror about the line of sight leaves the return image unmoved, so roll in that layout is invisible. The standard practice is three setups: the axis along X reads pitch, the axis along Y (rotated 90°) reads yaw, and roll is read by an electronic level riding on the stage (for horizontal travel) or by a roll-sensitive reflector such as a polygon. Each setup is integrated into its error curve.

Preparation

Mount the plane mirror near the stage centre with its normal on the autocollimator and good return over the full travel. Plan and mark the three setups, defining the positive angle direction of each relative to the machine frame. Calibrate the electronic level and record its zero. Move the stage at measurement speed or in steps, logging temperature and drive state.

Workflow diagram

01Mount the mirror02Setup 103Setup 204Level05Integrate the three curves06Report curves and indices

Procedure

  1. Mount the mirror and set the optical axis along travel (X); the reading direction corresponds to the pitch component.
  2. Step the stage through equally spaced positions and record two-axis readings; the vertical-plane component gives the pitch curve.
  3. Re-set the autocollimator from the side of the travel (axis along Y), repeat the steps and obtain the yaw curve.
  4. Place the electronic level on the stage and read the tilt along the travel for the roll curve (applicable to horizontal travel).
  5. Where needed, convert the three angular errors into linear error at the measuring point per the Abbe principle: Δ=ℓ·tanθ, ℓ being the offset from the motion axis.
  6. Report the three curves with peak values and periodic features, plus setup definitions and environment.

Calculation

Readings of the three setups give the angular error components after zeroing at setup. Angle-to-linear conversion follows Abbe: Δ(x)=ℓ·tan(θ(x))≈ℓ·θrad with θrad=θ″·π/648000. At a measuring point the three combine vectorially: Δtotal=ℓ1·tanθpitch+ℓ2·tanθyaw+ℓ3·tanθroll, the ℓ terms being the lever arms from the point to each rotation axis per machine geometry (illustrative relation).

Illustrative example

Schematic · not measured data
Schematic: three setups resolving pitch, yaw and roll; values illustrative.

Teaching data, not measured: over a 500 mm travel a station reads pitch +3″, yaw −2″ and roll +1″ (demonstration values). With lever arms of 300 mm, 200 mm and 150 mm to the respective axes, the linear effects are about 300·tan(3″)≈4.4 μm, 200·tan(2″)≈1.9 μm and 150·tan(1″)≈0.7 μm. The numbers only demonstrate the conversion.

Limitations

  • Assuming one plane mirror with a two-axis autocollimator captures all three angular errors including roll.
  • Undefined positive directions per setup flip signs in the compensation model.
  • Ignoring the Abbe offset and treating angular errors directly as linear ones.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

Method reference ↗ Method reference ↗ 
STEP BY STEP

Understand the measurement step by step

Principle schematic · not to scale
1 / 5
  1. The table steps along X with the mirror riding on it while the autocollimator reading moves.
  2. The pitch curve is drawn below with its extremes marked.
  3. The instrument moves to the side, the axis turns 90° and the yaw curve appears.
  4. The electronic level reads roll as the table moves and a third curve is added.
  5. All three convert to 300 mm: 4.95, 3.64 and 2.40 μm, labelled together.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Three angular errors of a precision XY stage over 300 mm travel

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

A 300 mm precision stage is checked before delivery for its three angular errors: pitch, yaw and roll. A plane mirror is fixed to the table; a two-axis autocollimator measures pitch along X and, after repositioning, yaw along Y. Roll cannot be read from a single plane mirror, so an electronic level reads it along the travel. Each error is converted to a linear value over 300 mm.

Setup and preparation

  • Mount the mirror at the table centre and level it with a dial gauge so its face is parallel to the travel within 0.02 mm/300 mm.

  • Set the autocollimator with its axis along X about 200 mm from the mirror, step the table 50 mm in one direction and take the vertical-plane component as pitch.

  • Move the instrument to the side with the axis along Y, repeat the seven positions and take the horizontal component as yaw.

  • Place the electronic level at the table centre and read the inclination in mm/m along the travel for roll.

  • Record the Abbe offset ℓ=150 mm from the measuring point to the axis of motion for converting angular error into linear error at the workpiece.

  • 20.3 °C, table unloaded, 3 s per station before reading.

Example data and records

  • x=0 mm: pitch +1.20″, yaw -0.60″, roll +0.0060 mm/m

  • x=50 mm: pitch +0.80″, yaw -0.20″, roll +0.0040 mm/m

  • x=100 mm: pitch -0.40″, yaw +0.50″, roll +0.0020 mm/m

  • x=150 mm: pitch -1.60″, yaw +1.40″, roll +0.0000 mm/m

  • x=200 mm: pitch -2.20″, yaw +1.90″, roll -0.0030 mm/m

  • x=250 mm: pitch -1.00″, yaw +1.10″, roll -0.0050 mm/m

  • x=300 mm: pitch +0.60″, yaw +0.20″, roll -0.0060 mm/m

  • Pitch and yaw come from two setups of the two-axis autocollimator; roll from an electronic level along the travel

  • Abbe offset ℓ=150 mm from the measuring point to the axis of motion

  • 20.3 °C; table unloaded and lubricated, stepped 50 mm in one direction

Calculation steps

Peak-to-valley of the three errors: pitch 3.40″ (+1.20″ to -2.20″), yaw 2.50″ (+1.90″ to -0.60″) and roll 0.0120 mm/m. Over 300 mm of travel: pitch 300×tan(3.40″)×1000=4.95 μm, yaw 300×tan(2.50″)×1000=3.64 μm and roll 0.0120 mm/m×200 mm of table width=2.40 μm. With the Abbe offset ℓ=150 mm the pitch contribution at the workpiece is 150×tan(3.40″)×1000=2.47 μm, so the same angular error produces about half the linear error at a short offset. Pitch dominates, while roll is smallest but still 2.40 μm across 200 mm and cannot be ignored.

Interpretation

Pitch 3.40″ (4.95 μm/300 mm), yaw 2.50″ (3.64 μm/300 mm) and roll 0.0120 mm/m (2.40 μm/200 mm). All three are inside the 0.02 mm/300 mm allowance.

Verification and pitfalls

  • Pitch and yaw need two separate setups: rotation of the mirror about the line of sight does not enter the reading, so roll cannot come from an autocollimator.

  • Roll is in mm/m, so multiply by the 200 mm table width; 0.0120 mm/m becomes 2.40 μm here.

  • Both setups must use the same table positions (the same 50 mm grid), otherwise the two curves are out of phase and fake a periodic error.

  • Measure the Abbe offset ℓ: the conversion is linear in ℓ, and 20 mm of error changes the result by 13 %.

  • Step the table in one direction only, since screw backlash adds directly to the pitch curve when reversing.