Guide attitude-angle inspection plan for a mechanical press slide
For pitch/yaw measurement over the full stroke of a mechanical press slide (300 mm stroke, example/teaching data), used to assess guide clearance uniformity and gib parallelism. The mirror is rigidly mounted on the slide; the autocollimator on a stable press-frame stand reads station by station, with bidirectional averaging.
Instruments
- Dual-axis photoelectric autocollimator (0.1″ class)
- Rigid mirror mounting fixture for the slide
- Two dial indicators with magnetic bases (auxiliary comparison, example)
- Station positioning and temperature logging tools
Procedure
- Confirm the 300 mm stroke (example), 50 mm station spacing, datum and sign convention.
- Mount the mirror rigidly on the slide face and verify against loosening; fix the autocollimator on a stable press-frame stand and check the return beam over full travel.
- Inch the slide downward, stopping every 50 mm; after settling, read pitch and yaw to 0.1″.
- Repeat at the same stations upward; average both directions and log the differences.
- Place one dial indicator against the guide face at two diagonal corners of the slide and record clearance change for comparison.
- Integrate the angles into an attitude curve and convert to guide-clearance changes at the four corners via the corner geometry.
- Deliver the attitude-angle curves, clearance conversion table, bidirectional comparison and guide adjustment advice.
Calculation
Guide clearance change at each corner Δgi≈θpitch·yi+θyaw·xi (small-angle approximation), with xi, yi the corner coordinates from the slide centre. 1″ over a 1000 mm guide length ≈4.85 μm attitude difference (example/teaching data).
Reporting
- Mirror mounting rigidity verified
- No creeping readings at stations
- Bidirectional differences corroborated by dial indicators
Limitations
Static station readings do not reflect guide behaviour under dynamic stamping loads; the 3D wear distribution of the guides needs contact measurement. Clearance conversion uses the small-angle approximation; note when exceeded.
Understand the measurement step by step
- 01
Confirm the 300 mm stroke (example), 50 mm station spacing, datum and sign convention.
- 02
Mount the mirror rigidly on the slide face and verify against loosening; fix the autocollimator on a stable press-frame stand and check the return beam over full travel.
- 03
Inch the slide downward, stopping every 50 mm; after settling, read pitch and yaw to 0.1″.
- 04
Repeat at the same stations upward; average both directions and log the differences.
- 05
Place one dial indicator against the guide face at two diagonal corners of the slide and record clearance change for comparison.
- 06
Integrate the angles into an attitude curve and convert to guide-clearance changes at the four corners via the corner geometry.
- 07
Deliver the attitude-angle curves, clearance conversion table, bidirectional comparison and guide adjustment advice.
- Lock the slide · Slide at BDC and mechanically locked.
- Set optical axis · Optical axis vertical along the column guide.
- Step along face · The 200 mm bridge climbs the guide face.
- Log readings · Pitch readings logged per segment.
- Evaluate deviation · Cumulative conversion gives the guide deviation.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Mechanical Press Slide Guide Angular Deviation Inspection · Tutorial Case
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: segmented angular survey of the column guide faces within a press slide guide deviation test; data are instructional settings.
Setup and preparation
Park the slide at bottom dead centre and mechanically lock it
Mount the autocollimator on the bed with the optical axis vertical along the column guide
Step a 200 mm bridge up against the guide face
Record the pitch reading per segment
Cumulate and convert for guide angular deviation
Example data and records
Bridge span L=200 mm; segment 1 autocollimator reading θ₁=-1.8″
Segment 2 autocollimator reading θ₂=+1.2″
Segment 3 autocollimator reading θ₃=-0.6″
Calculation steps
Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 200×tan(-1.8″)=-1.75 μm; Segment 2: 200×tan(+1.2″)=+1.16 μm; Segment 3: 200×tan(-0.6″)=-0.58 μm. Cumulative heights: 0→-1.75→-0.59→-1.17 μm; peak-to-valley PV=+0.00−(-1.75)=+1.75 μm.
Interpretation
Tutorial result PV≈1.75 μm, demonstrating measurement and evaluation of slide guide geometry error.
Verification and pitfalls
Slide locking confirmed against accidental descent
Bridge seated tightly on the guide face
Measure up and down passes and average