MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Flatness inspection plan for a surface grinder table
DOWNLOADABLE MEASUREMENT PLAN

Flatness inspection plan for a surface grinder table

For installation acceptance and periodic re-inspection of a rectangular surface grinder table (800×400 mm, example/teaching data). An autocollimator measures the straightness of grid lines; heights are tied to a common datum through shared intersection nodes to build a full-surface height matrix. The evaluation method (minimum zone or least squares) must be agreed before measurement and the two results must never share the same name. Sequence: agree datum and method, lay out stations and measure, convert and evaluate, then run a reverse check and deliver records.

Instruments

Procedure

Calculation

Δh=L·tanθ; with L=100 mm, 1″≈0.485 μm (example/teaching data). After tying all lines to a common datum, flatness f_MZ is the separation of the minimum-zone enclosing planes. The least-squares residual peak-to-valley is for comparison only; the two must not be named interchangeably.

Reporting

Limitations

Covers geometric flatness only; grinding heat, material ageing and dynamic accuracy are excluded. Deformation under heavy load requires separate assessment, and data are not comparable with other support states.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Agree in the requirements record: useful area 800×400 mm (example), support state, 100 mm line spacing and minimum-zone evaluation. Without a specified tolerance, report data without a pass/fail decision.

  2. 02

    Clean the table and lay out 5 longitudinal lines, 3 transverse lines and 2 diagonals with a 100 mm span; label stations and log ambient temperature.

  3. 03

    Align the autocollimation path and check the return beam over full travel; acquire angular readings to 0.1″ line by line with a fixed sign convention and no re-zeroing partway.

  4. 04

    Integrate angles into heights via Δh=L·tanθ and tie all lines to one reference plane through shared intersection nodes, forming a height matrix.

  5. 05

    Evaluate flatness as the separation of the two minimum-zone enclosing planes; also give the least-squares residual peak-to-valley as a clearly labelled reference.

  6. 06

    Reverse-repeat one diagonal and one longitudinal line; compare closure and pointwise differences and re-measure if they exceed the agreed limit.

  7. 07

    Deliver the layout drawing, raw angle table, height matrix, evaluation results, environment log and uncertainty statement.

Principle schematic · not to scale
1 / 5
  1. Set up instrument · Mount the autocollimator on the stand with the optical axis aligned to the table.
  2. Place bridge · Set the 150 mm bridge with the reflector fixed at its centre.
  3. Read per step · Move the bridge end-to-end over three steps and record each angle.
  4. Convert heights · Convert arc-second readings into micrometre height differences via Δh=L·tan(θ).
  5. Cumulate & evaluate · Cumulate segment heights and obtain the peak-to-valley flatness.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Surface Grinder Table Flatness Inspection · Tutorial Case

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: segmented flatness inspection of a surface grinder electromagnetic worktable in a training workshop; span and readings are instructional data.

Setup and preparation

  • Clean the worktable and level the bed on adjusting shims

  • Mount the autocollimator on a rigid stand beside the grinder, optical axis parallel to table travel

  • Use a 150 mm bridge with the reflector at its centre

  • Move the bridge end-to-end from one end of the table, recording angular readings per step

  • Record 20 °C and process the three readings

Example data and records

  • Bridge span L=150 mm; segment 1 autocollimator reading θ₁=+0.8″

  • Segment 2 autocollimator reading θ₂=-1.2″

  • Segment 3 autocollimator reading θ₃=+1.6″

Calculation steps

Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 150×tan(+0.8″)=+0.58 μm; Segment 2: 150×tan(-1.2″)=-0.87 μm; Segment 3: 150×tan(+1.6″)=+1.16 μm. Cumulative heights: 0→+0.58→-0.29→+0.87 μm; peak-to-valley PV=+0.87−(-0.29)=+1.16 μm.

Interpretation

Tutorial result PV≈1.16 μm, demonstrating the micrometre-level flatness evaluation workflow; compliant against a 0.005 mm teaching tolerance.

Verification and pitfalls

  • Bridge feet contact the table without gaps or burr interference

  • Repeat each reading twice; differences must not exceed 0.2″

  • Check the cumulative sign convention: rise positive, fall negative