ObjectSix-axis robot, 1.5 m reach
InitialBase pitch 0.3°, roll 0.1°
InstrumentElectronic level + laser tracker
TargetTool position error ≤ 0.5 mm
Compute before adjusting
0.3° at 1.5 m is 7.8 mm, far above the 0.5 mm target.
0.1° roll is 2.6 mm, also significant.
Level, then calibrate
Level within 0.02°, then establish base and tool frames.
Multi-pose residual after calibration: 0.28 mm maximum.
Case workflow, animated
1 / 4
- Confirm the task and datum
- Lay out stations by span
- Acquire readings and convert
- Evaluate and verify
The animation follows the station layout and calculation order of this case. Values are teaching data.
ConclusionLevelling reduced the error from 7.8 mm to 0.28 mm; calibrating first wastes the effort.
Teaching example. Calibration and safety configuration require authorised personnel.
Recommended instruments

Zhongji high-speed electronic autocollimator accuracy 1″
MC030-ZJHS200-200HZ

Zhongji high-speed electronic autocollimator accuracy 2″
MC030-ZJPX200-2350HZ

Zhongji high-speed electronic autocollimator accuracy 1″
MC030-ZJPX300-2350HZ