MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Robot cell: 0.3° base tilt becomes 2 mm at reach
CASE 22 · TEACHING DATA

Robot cell: 0.3° base tilt becomes 2 mm at reach

Base level is often treated as approximate. Over a 1.5 m reach, 0.3° is 7.8 mm at the tool; level first, then calibrate.

ObjectSix-axis robot, 1.5 m reach
InitialBase pitch 0.3°, roll 0.1°
InstrumentElectronic level + laser tracker
TargetTool position error ≤ 0.5 mm
cos errormotion axismeasuring line

Compute before adjusting

0.3° at 1.5 m is 7.8 mm, far above the 0.5 mm target.

0.1° roll is 2.6 mm, also significant.

Level, then calibrate

Level within 0.02°, then establish base and tool frames.

Multi-pose residual after calibration: 0.28 mm maximum.

Case workflow, animated

LEDBeamsplitterImage planeReturn beam retraces and splits againSchematic · not to scale · not measured data
1 / 4
  1. Confirm the task and datum
  2. Lay out stations by span
  3. Acquire readings and convert
  4. Evaluate and verify

The animation follows the station layout and calculation order of this case. Values are teaching data.

ConclusionLevelling reduced the error from 7.8 mm to 0.28 mm; calibrating first wastes the effort.

Teaching example. Calibration and safety configuration require authorised personnel.

Recommended instruments