One section only tells you how far the spot is offset, not whether the cause is translation or tilt. Two sections at a known separation separate the two.

Object2.5 m optical system, two target sections
InstrumentDual-axis autocollimator with crosshair targets on plane mirrors
CriteriaMid-point offset ≤ 0.05 mm, tilt ≤ 10″ (teaching assumption)
cos errormotion axismeasuring line

Separate the two errors first

Offset is a translation of the whole axis; tilt is a rotation. The first is corrected by translating an element, the second by rotating it, so the remedies differ completely.

Adjusting at a single section easily compensates tilt as if it were offset, which makes the deviation worse at another position.

Readings

The sections are L = 2.5 m apart. Referenced to the same datum, section 1 shows a lateral offset d₁ = +0.12 mm and section 2 shows d₂ = −0.08 mm.

Readings were taken at the target crosshair centre; repeatability of both was within 0.01 mm, which supports the following calculation.

Calculation

Tilt θ = (d₂ − d₁)/L = (−0.08 − 0.12)/2500 = −80 μrad, about −16.5″. The negative sign means the axis tilts toward section 2.

Mid-point offset = (d₁ + d₂)/2 = 0.02 mm. Aiming at the mid-point, remove tilt first and then translate to avoid iteration.

Conclusion and limits

The 0.02 mm mid-point offset meets 0.05 mm, but the 16.5″ tilt exceeds 10″, so tilt must be adjusted. Rotate first, translate second, and one iteration should converge.

Two sections describe straightness only between those points. For long systems with several elements, add sections, otherwise a bend in the middle stays hidden.

Case workflow, animated

LEDBeamsplitterImage planeReturn beam retraces and splits againSchematic · not to scale · not measured data
1 / 4
  1. Confirm the task and datum
  2. Lay out stations by span
  3. Acquire readings and convert
  4. Evaluate and verify

The animation follows the station layout and calculation order of this case. Values are teaching data.

Conclusion0.02 mm offset passes, 16.5″ tilt fails; remove tilt before translating.

Teaching data. Real systems need a number of sections matched to the element count and path length, with environment and mounting recorded.