MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Coaxiality and runout by two sections
MEASUREMENT METHOD

Coaxiality and runout by two sections

Evaluate shaft and bore alignment, separating radial offset from angular tilt.

Principle

The line joining two section centres defines the actual axis; the extreme deviation from the datum is coaxiality.

Preparation

Define the datum axis, section spacing and rotation state. Clean fits and mark sections and directions.

Workflow diagram

01Set two sections02Rotate and acquire03Fit centres04Split components05Evaluate to datum

Procedure

  1. Place targets or mirrors in two sections near both ends.
  2. Rotate the part and read angle or displacement per section.
  3. Fit each section centre to obtain offset and tilt.
  4. Compute coaxiality to the datum and split radial and angular components.
  5. Report sections, fitted circles, components and datum.

Calculation

θ ≈ (e₂ − e₁)/L. Coaxiality is twice the maximum radial deviation from the datum, per the chosen definition.

Illustrative example

Schematic · not measured data
Schematic: two-section fit and component separation.

Example: e = 5 and 15 μm over 400 mm gives about 5″ tilt and 30 μm diameter coaxiality.

Limitations

  • One section gives offset but not tilt.
  • A different datum axis gives a different result.
  • Rotation error enters unless both directions are measured.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

STEP BY STEP

Understand the measurement step by step

Principle schematic · not to scale
1 / 5
  1. Step 1 · Place targets or mirrors in two sections near both ends.
  2. Step 2 · Rotate the part and read angle or displacement per section.
  3. Step 3 · Fit each section centre to obtain offset and tilt.
  4. Step 4 · Compute coaxiality to the datum and split radial and angular components.
  5. Step 5 · Report sections, fitted circles, components and datum.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Worked two-section coaxiality example over 400 mm

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching example: two sections 400 mm apart show eccentricities of 12.0 µm and 8.0 µm in opposite phase; coaxiality and tilt are evaluated against the line joining the two centres.

Setup and preparation

  • Place targets or mirrors in two sections near both ends.

  • Rotate the part and read angle or displacement per section.

  • Fit each section centre to obtain offset and tilt.

  • Compute coaxiality to the datum and split radial and angular components.

Example data and records

  • Section A: 12.0 µm at 0°; section B: 8.0 µm at 180°.

  • Eight angular positions per section, circle fitted for centre and residuals.

  • The centre line is tilted about 10304.66″ to the axis.

Calculation steps

With opposite phase, coaxiality = e₁ + e₂ = 20 µm; tilt = arctan(20/400) = 10304.66″. For in-phase errors the difference applies instead.

Interpretation

Coaxiality constrains only the two section centres; it says nothing about the middle of the part. Add intermediate sections for slender parts.

Verification and pitfalls

  • Fix the datum first: common axis, two-centre line or maximum inscribed cylinder give different numbers.

  • Record the rotary angle at every reading, otherwise the phase is lost.

  • Report runout and coaxiality separately; they are different definitions.