Principle
Angle gauges are calibrated material standards, used singly or wrung into stacks for the required angle. Gauge stack and workpiece sit on a common surface plate while the autocollimator sights first the gauge face and then the workpiece face. Parallel faces bring the return images into coincidence at zero; the reading difference is the deviation of the workpiece angle from the gauge angle, with sign set by the sense of rotation. The autocollimator handles only the small difference, so the dominant errors are the gauge uncertainty and the form error of the measured face.
Preparation
Check the gauge certificates and choose a stack with as few blocks as possible to limit wringing errors. Clean gauges and workpiece faces and inspect for burrs and wringing quality. Ensure a stable plate or table and an autocollimator distance giving clear returns from both faces. Record temperature and avoid transferring hand heat to the gauges.
Workflow diagram
Procedure
- Compose a gauge stack for the nominal angle and sum the individual corrections.
- Place the stack and workpiece on the plate with both measuring faces toward the autocollimator at equal height.
- Sight the gauge face centre and record the stable reading A1.
- Without moving the instrument, sight the corresponding workpiece position and record A2, adjusting the support if needed to bring the return into range.
- The deviation is Δθ=A2−A1; workpiece angle = stack angle (with corrections) plus Δθ under the sign convention.
- Repeat at several positions on the face to assess form effects and report the result with uncertainty.
Calculation
Reading difference Δθ=A2−A1 in arcsec. The measured angle α=αstack+Σc+s·Δθ, with αstack the nominal stack angle, Σc the sum of gauge corrections and s the sign (+1 or −1) fixed by the relation between reading direction and angle increase, verified beforehand. Conversion: 1″≈4.848×10⁻⁶ rad. Stack uncertainty combines block uncertainties and wringing effects.
Illustrative example
Teaching data, not measured: a nominal 30° angle with a 30° stack corrected by +1.5″. Readings A1=−2.0″ and A2=+0.5″ give Δθ=+2.5″. With the verified sign s=−1, the angle is 30°+1.5″−2.5″=29°59′59″. The numbers only demonstrate the calculation chain.
Limitations
- An unverified sign convention reverses the difference and biases every result.
- Poor flatness of the measured face makes position-to-position spreads masquerade as angle deviation.
- Excessive block count or poor wringing adds avoidable error.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.