Splice flatness inspection plan for optical breadboards
For splice flatness and seam steps after joining multiple optical breadboards into one surface (2×1 pieces of 600×900 mm, example/teaching data). Support per the vendor's recommended array, measure the full surface on a grid, evaluate against a least-squares reference and report seam steps separately.
Instruments
- Photoelectric autocollimator (0.1″ class) with 100 mm reflector base (example)
- Equal-height levelling supports per the vendor's recommended array
- Seam densification station markers
- Temperature logger
Procedure
- Confirm the 2×1 splice layout (example), support array and least-squares evaluation agreement.
- Level each board before joining; after joining, lay out a 100 mm grid over the full surface with densified stations on both sides of each seam.
- Read each grid line with the autocollimator to 0.1″ with a fixed sign convention.
- Tie all lines to a common datum into a height matrix and fit a least-squares reference plane.
- Evaluate splice flatness (residual peak-to-valley) and report each seam step separately.
- Unclamp and re-clamp the supports, then repeat key grid lines to assess clamping repeatability.
- Deliver the height matrix, flatness, seam step table and clamping repeatability record.
Calculation
The least-squares plane z=ax+by+c minimises squared residuals; flatness is the residual peak-to-valley. Seam step is the height difference of the nearest stations on both sides of the seam. With L=100 mm, 1″≈0.485 μm (example/teaching data).
Reporting
- Support array matches the vendor recommendation
- Seam densification stations included
- Re-clamp repeatability difference recorded
Limitations
Local stiffness variations of the honeycomb make high-frequency waviness between spans unmeasurable; this plan evaluates the mechanical mounting surface only, not optical figure or isolation performance.
Understand the measurement step by step
- 01
Confirm the 2×1 splice layout (example), support array and least-squares evaluation agreement.
- 02
Level each board before joining; after joining, lay out a 100 mm grid over the full surface with densified stations on both sides of each seam.
- 03
Read each grid line with the autocollimator to 0.1″ with a fixed sign convention.
- 04
Tie all lines to a common datum into a height matrix and fit a least-squares reference plane.
- 05
Evaluate splice flatness (residual peak-to-valley) and report each seam step separately.
- 06
Unclamp and re-clamp the supports, then repeat key grid lines to assess clamping repeatability.
- 07
Deliver the height matrix, flatness, seam step table and clamping repeatability record.
- Splice set-up · Two breadboards spliced and torqued.
- Aim at joint · Autocollimator aimed along the splice.
- Cross-joint survey · The 150 mm bridge steps across the joint.
- Compare readings · Joint and off-joint readings compared.
- Step evaluation · Height conversion gives the splice step.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Optical Breadboard Splice Flatness Inspection · Tutorial Case
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: segmented measurement of step height and alignment across a splice between two optical breadboards; data are instructional settings.
Setup and preparation
Splice and clamp the two breadboards on the isolation table
Aim the autocollimator along the splice direction
Survey with a 150 mm bridge crossing the joint step by step
Record the angular reading per segment
Compare heights of joint-crossing and plain segments
Example data and records
Bridge span L=150 mm; segment 1 autocollimator reading θ₁=+0.3″
Segment 2 autocollimator reading θ₂=-0.6″
Segment 3 autocollimator reading θ₃=+0.9″
Calculation steps
Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 150×tan(+0.3″)=+0.22 μm; Segment 2: 150×tan(-0.6″)=-0.44 μm; Segment 3: 150×tan(+0.9″)=+0.65 μm. Cumulative heights: 0→+0.22→-0.22→+0.43 μm; peak-to-valley PV=+0.43−(-0.22)=+0.65 μm.
Interpretation
Tutorial result PV≈0.65 μm, demonstrating evaluation of the splice step height.
Verification and pitfalls
Dowels and screws torqued to specification
When crossing the joint the bridge feet straddle both boards
Do not touch the table during readings