Angle to height
Δh = 1500 × tanθ per station; accumulated: +0.000, +0.000, +0.023, +0.033, +0.027, +0.011, +0.014 mm.
Total range 0.033 mm is inside 0.08 mm, but a reversal of +10 μm between stations 2 and 3 marks a high roller.
Closure check
Returning to the start, +0.4″ corresponds to 0.003 mm, effectively closed.
A larger closure points to a knocked base, airflow or drift.
Adjustment
Adjust the single offending roller rather than re-setting the section; re-measure with the same span.
Case workflow, animated
- Confirm the task and datum
- Lay out stations by span
- Acquire readings and convert
- Evaluate and verify
The animation follows the station layout and calculation order of this case. Values are teaching data.
Teaching data. Lehr adjustment requires a stopped line and hot-work procedures.