MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Turbine blade setting angle: twist from four corners
CASE 28 · TEACHING DATA

Turbine blade setting angle: twist from four corners

Setting-angle error changes the flow area and efficiency. Four corner readings give a twist figure that describes the whole blade, not one point.

ObjectLast-stage blade, four corners, 300 mm height
InstrumentAutocollimator with a blade fixture
Readings+18 / +2 / −3 / −4 ″ clockwise
CriterionSetting angle ±15″, twist ≤ 10″
h_i = sum L tan(theta)

What four corners mean

Each corner is a local setting angle; the mean is the overall angle and the diagonal difference is twist.

One corner can pass while the whole blade is twisted.

Work the numbers

Mean angle = +3.2″, inside ±15″.

Twist = +15″, outside the 10″ limit.

What to do

A good mean with bad twist means root datum and tip constraint disagree. Check cleanliness and clamp sequence instead of rotating the blade to fix the mean.

Case workflow, animated

Image point (x, y)αX for pitch, Y for yawθx = x/2f, θy = y/2fSchematic · not to scale · not measured data
1 / 4
  1. Confirm the task and datum
  2. Lay out stations by span
  3. Acquire readings and convert
  4. Evaluate and verify

The animation follows the station layout and calculation order of this case. Values are teaching data.

ConclusionMean +3.2″ passes, twist +15″ fails; the cause is clamping, not the angle.

Teaching data. Blade assembly follows the turbine maker process documents.