MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Yaw bearing housing: separating offset from tilt with two sections
CASE 23 · TEACHING DATA

Yaw bearing housing: separating offset from tilt with two sections

If the two mounting faces of a yaw bearing housing are not coaxial, the gear mesh is periodically overloaded. Two target sections in one set-up give both offset and tilt.

Object2.4 m yaw bearing housing, two sections 1.8 m apart
InstrumentDual-axis autocollimator, two-section target, rotary fixture
ReadingsSection 1: +180 μm, section 2: -60 μm
CriterionCoaxiality ≤ 0.10 mm; tilt ≤ 30″ per assembly spec
h_i = sum L tan(theta)

Why two sections

One section gives offset at that height only and cannot separate translation from tilt about the base. Translation is shimmed; tilt needs re-machining.

Subtract the two readings and divide by the spacing for tilt; average them for the mean offset.

Work the numbers

Mean offset = 60 μm against 100 μm: pass.

Tilt = 27.5″ against 30″: pass, with only 8% margin.

How to use the two numbers

Offset within limits: correct with shims. Tilt passes but with little margin, so tighten diagonally and re-measure after final torque; tightening order shifts tilt at the 10″ level.

Case workflow, animated

Image point (x, y)αX for pitch, Y for yawθx = x/2f, θy = y/2fSchematic · not to scale · not measured data
1 / 4
  1. Confirm the task and datum
  2. Lay out stations by span
  3. Acquire readings and convert
  4. Evaluate and verify

The animation follows the station layout and calculation order of this case. Values are teaching data.

ConclusionTwo sections separate 60 μm offset from 27.5″ tilt; the first is shimmed, the second controlled by tightening.

Teaching data. Use the OEM assembly specification for acceptance; this is not an acceptance result for any machine.