Automotive & New Energy
Inspection fixtures, assembly tooling, machining equipment and electric-drive test stands.
Methods
- Production fixture references
- Machine axis geometry
- Assembly plane alignment
- Rotary indexing
Procedure
- Define inspection targets
- Check references
- Measure key features
- Adjust
- Verify and record
The actual inspection plan must reflect drawing tolerances and production conditions.
Typical measurement scenarios in this industry
Each scenario gives the object, tolerance range and method, ready to take to the selector.
Body-in-white fixture datum consistency
Across stations on the main line, one optical axis ties datum holes and locating faces together to check whether station-to-station deviation exceeds the 0.1 mm window.
Wide-field electronic autocollimators↗Battery tray flatness and sealing face
Trays of 1–2 m need 0.2–0.5 mm flatness along the seal groove. Sample along the sealing path, not only on a central grid.
Metrology autocollimator series↗Cylinder block main-bore coaxially
For long bores, a centred mirror target in each bore gives centre offset, faster than a mandrel and directly referenced to the first bore.
Machine-tool autocollimator series↗Paint and weld robot base levelling
Base level directly affects TCP accuracy, typically within 0.2 mm/m; re-check parallelism to the track at the same time.
Zhongji automatic measurement series↗End-of-line station cycle time and repeatability
A line takt allows 10 s per measurement. Run 30 repeats first and confirm 2σ is below one tenth of the tolerance band before release.
Zhongji high-speed dynamic autocollimators↗Coplanarity of welding fixture datum faces
Coplanarity of BIW welding fixture datum faces drives body accuracy; check periodically by autocollimator grid method, typically 0.05–0.1 mm.
Machine-tool autocollimator series↗Understand the measurement step by step
- 01
Define inspection targets
- 02
Check references
- 03
Measure key features
- 04
Adjust
- 05
Verify and record
- Identify fixture datums · Use the fixture drawing to identify datum direction A and compared direction B, specifying suitable reference mirrors, angle references or other direction-transfer devices.
- Check references · Check reference calibration and mounting. Maintain specified support, clamping and temperature conditions, documenting the direction definitions as well as readings.
- Measure angular error · Repeat the angle comparison, apply known reference corrections and report the signed deviation from 90°.
- Interpret length effect · Convert the direction error to an illustrative displacement over a specified length. For surface-perpendicularity acceptance, add surface sampling, form error and complete datum rules.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Automotive fixture: converting a right-angle direction error to a length effect
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project. Two reference directions on a powertrain assembly fixture illustrate how a departure from 90° produces a directional offset over 400 mm. This is not a complete surface-perpendicularity inspection.
Setup and preparation
Use the fixture drawing to identify datum direction A and compared direction B, specifying suitable reference mirrors, angle references or other direction-transfer devices.
Check reference calibration and mounting. Maintain specified support, clamping and temperature conditions, documenting the direction definitions as well as readings.
Repeat the angle comparison, apply known reference corrections and report the signed deviation from 90°.
Convert the direction error to an illustrative displacement over a specified length. For surface-perpendicularity acceptance, add surface sampling, form error and complete datum rules.
Example data and records
Illustrative included angle: 90°+3.00″.
Length of interest L=400 mm; only the directional angular component is calculated.
No drawing tolerance is specified, so no pass/fail decision is made.
Calculation steps
δ=3.00″=3π/648000 rad; e=L tanδ=400×1000×tan(3π/648000)≈5.817764 μm.
Interpretation
The angular component produces an illustrative offset of approximately 5.817764 μm over 400 mm. It explains assembly-direction sensitivity, not complete fixture or part acceptance.
Verification and pitfalls
Check the right-angle reference or direction-transfer error rather than attributing it entirely to the fixture.
Clamped and unclamped states can differ; verify the state required by the drawing.
Actual surface perpendicularity also depends on form, sampling coverage and datum construction.