Lithium Battery Manufacturing Equipment
Coater oven rollers, winding mandrels, stacking tables, die-cutting tools, electrolyte filling and sealing fixtures
Methods
- Parallelism of coater roller axes
- Verticality of winding mandrel axes
- Flatness of stacking tables
- Parallelism of die-cutting upper and lower tools
- Straightness of electrode web travel
Procedure
- Level the frame
- Check roller parallelism
- Check mandrel verticality
- Re-measure under web tension
- Record
Geometric checks do not replace coating thickness consistency tests, electrode alignment inspection, or cell electrical and safety testing.
Understand the measurement step by step
- 01
Level the frame
- 02
Check roller parallelism
- 03
Check mandrel verticality
- 04
Re-measure under web tension
- 05
Record
- Mark nodes · Mark five nodes along a line on the reference beam above the rollers at 50 mm spacing (total 200 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 50 mm sampling step.
- Align optics · Set up the autocollimator using the mounting face on the oven side wall for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
- Integrate · Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
- Reverse run · Repeat the run in reverse over the same nodes, compare the two residual profiles and keep the raw angles together with before-and-after adjustment records.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Teaching example: parallelism of coating rollers
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: a 200 mm section of a coating oven roller shows how interval angles from autocollimation are reconstructed into a height profile. The values are teaching assumptions and are not acceptance limits for lithium battery manufacturing.
Setup and preparation
Mark five nodes along a line on the reference beam above the rollers at 50 mm spacing (total 200 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 50 mm sampling step.
Set up the autocollimator using the mounting face on the oven side wall for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
Read and retain the raw angle of every interval rather than a smoothed display value, and log ambient temperature, time of measurement, and conditions such as oven radiation and web tension.
Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
Example data and records
Interval angles: 0.5″, 0.3″, −0.4″, 0.2″.
Span and sampling step: 50 mm, four intervals; the first node is defined as 0 μm.
Cumulative node heights: 0.000, 0.121, 0.194, 0.097, 0.145 μm; residuals against the endpoint line: 0.000, 0.085, 0.121, −0.012, 0.000 μm.
Calculation steps
For each interval Δh = 50×1000×tan(θ·π/648000) μm. With the four angles this gives Δh ≈ 0.121, 0.073, −0.097, 0.048 μm; cumulative heights are 0.000, 0.121, 0.194, 0.097, 0.145 μm, residuals after removing the endpoint line are 0.000, 0.085, 0.121, −0.012, 0.000 μm and the peak-to-valley value is 0.133 μm.
Interpretation
For the given sampling and endpoint reference the residual peak-to-valley of a line on the reference beam above the rollers is about 0.133 μm. It describes only the static geometry of this 200 mm line and is not an acceptance conclusion for lithium battery manufacturing.
Verification and pitfalls
Confirm that the reflector span matches the actual sampling step; the simple integration model cannot be applied when they differ.
A reverse run shows repeatability only and does not remove contact deformation or thermal drift of a coating oven roller; oven radiation and web tension must be assessed separately.
Any report must state the reference, evaluation algorithm, tolerance and measurement uncertainty.