Forging and Press Equipment

Upper crowns, columns, slides, beds, guide plates and lower crowns

Methods

Procedure

  1. Prepare foundation and shims
  2. Level the lower crown
  3. Check column verticality
  4. Adjust the slide
  5. No-load re-verification

Geometric checks do not replace full-load press trials, frame stiffness and fatigue assessment, or forged-part dimensional and metallurgical inspection.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Prepare foundation and shims

  2. 02

    Level the lower crown

  3. 03

    Check column verticality

  4. 04

    Adjust the slide

  5. 05

    No-load re-verification

Principle schematic · not to scale
1 / 4
  1. Mark nodes · Mark five nodes along a line on the bed top face at 100 mm spacing (total 400 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 100 mm sampling step.
  2. Align optics · Set up the autocollimator using the machined face of the lower crown for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
  3. Integrate · Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
  4. Reverse run · Repeat the run in reverse over the same nodes, compare the two residual profiles and keep the raw angles together with before-and-after adjustment records.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Teaching example: levelness of a press bed

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: a 400 mm section of a press bed shows how interval angles from autocollimation are reconstructed into a height profile. The values are teaching assumptions and are not acceptance limits for forging and press equipment.

Setup and preparation

  • Mark five nodes along a line on the bed top face at 100 mm spacing (total 400 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 100 mm sampling step.

  • Set up the autocollimator using the machined face of the lower crown for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.

  • Read and retain the raw angle of every interval rather than a smoothed display value, and log ambient temperature, time of measurement, and conditions such as frame residual heat and foundation vibration.

  • Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.

Example data and records

  • Interval angles: 1.6″, −1.0″, 0.7″, −0.3″.

  • Span and sampling step: 100 mm, four intervals; the first node is defined as 0 μm.

  • Cumulative node heights: 0.000, 0.776, 0.291, 0.630, 0.485 μm; residuals against the endpoint line: 0.000, 0.654, 0.048, 0.267, 0.000 μm.

Calculation steps

For each interval Δh = 100×1000×tan(θ·π/648000) μm. With the four angles this gives Δh ≈ 0.776, −0.485, 0.339, −0.145 μm; cumulative heights are 0.000, 0.776, 0.291, 0.630, 0.485 μm, residuals after removing the endpoint line are 0.000, 0.654, 0.048, 0.267, 0.000 μm and the peak-to-valley value is 0.654 μm.

Interpretation

For the given sampling and endpoint reference the residual peak-to-valley of a line on the bed top face is about 0.654 μm. It describes only the static geometry of this 400 mm line and is not an acceptance conclusion for forging and press equipment.

Verification and pitfalls

  • Confirm that the reflector span matches the actual sampling step; the simple integration model cannot be applied when they differ.

  • A reverse run shows repeatability only and does not remove contact deformation or thermal drift of a press bed; frame residual heat and foundation vibration must be assessed separately.

  • Any report must state the reference, evaluation algorithm, tolerance and measurement uncertainty.