Mining Machinery
Crusher frames, mill shells and trunnion bearings, hoist shafts and drums, belt conveyor frames, excavator slewing-bearing mounting faces
Methods
- Levelness of frame mounting faces
- Coaxiality of mill axis and bearings
- Datum for girth-gear face runout
- Straightness of conveyor frames
- Flatness of slewing-bearing mounting faces
Procedure
- Accept the foundation
- Measure the frame in place
- Align axes
- Adjust levelling pads
- No-load re-check
Geometric checks do not replace load trials, gear contact-pattern inspection, or long-term foundation settlement monitoring.
Understand the measurement step by step
- 01
Accept the foundation
- 02
Measure the frame in place
- 03
Align axes
- 04
Adjust levelling pads
- 05
No-load re-check
- Mark nodes · Mark five nodes along a longitudinal line on the bearing base at 100 mm spacing (total 400 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 100 mm sampling step.
- Align optics · Set up the autocollimator using the embedded plate in the concrete foundation for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
- Integrate · Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
- Reverse run · Repeat the run in reverse over the same nodes, compare the two residual profiles and keep the raw angles together with before-and-after adjustment records.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Teaching example: levelness of a mill trunnion bearing base
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: a 400 mm section of a ball-mill trunnion bearing base shows how interval angles from autocollimation are reconstructed into a height profile. The values are teaching assumptions and are not acceptance limits for mining.
Setup and preparation
Mark five nodes along a longitudinal line on the bearing base at 100 mm spacing (total 400 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 100 mm sampling step.
Set up the autocollimator using the embedded plate in the concrete foundation for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
Read and retain the raw angle of every interval rather than a smoothed display value, and log ambient temperature, time of measurement, and conditions such as dust and slow foundation settlement.
Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
Example data and records
Interval angles: 1.0″, 0.8″, −1.2″, −0.4″.
Span and sampling step: 100 mm, four intervals; the first node is defined as 0 μm.
Cumulative node heights: 0.000, 0.485, 0.873, 0.291, 0.097 μm; residuals against the endpoint line: 0.000, 0.461, 0.824, 0.218, 0.000 μm.
Calculation steps
For each interval Δh = 100×1000×tan(θ·π/648000) μm. With the four angles this gives Δh ≈ 0.485, 0.388, −0.582, −0.194 μm; cumulative heights are 0.000, 0.485, 0.873, 0.291, 0.097 μm, residuals after removing the endpoint line are 0.000, 0.461, 0.824, 0.218, 0.000 μm and the peak-to-valley value is 0.824 μm.
Interpretation
For the given sampling and endpoint reference the residual peak-to-valley of a longitudinal line on the bearing base is about 0.824 μm. It describes only the static geometry of this 400 mm line and is not an acceptance conclusion for mining.
Verification and pitfalls
Confirm that the reflector span matches the actual sampling step; the simple integration model cannot be applied when they differ.
A reverse run shows repeatability only and does not remove contact deformation or thermal drift of a ball-mill trunnion bearing base; dust and slow foundation settlement must be assessed separately.
Any report must state the reference, evaluation algorithm, tolerance and measurement uncertainty.