Port Cranes
Portal frames and legs, main girders, trolley rails, slewing bearings, boom-hinge points of ship-to-shore cranes
Methods
- Verticality of portal legs
- Girder camber and straightness
- Straightness and elevation of trolley rails
- Parallelism of the two rail lines
- Coaxiality of boom-hinge axes
Procedure
- Re-survey the rail foundation
- Align the portal frame
- Measure girders
- Adjust rails
- Re-verify before loading
Geometric checks do not replace rated-load tests, structural stress monitoring, or wind-resistance and anti-overturning verification.
Recommended instruments


Dual-axis electronic autocollimator accuracy 0.2″ maximum measuring distance 30m

Dual-axis electronic autocollimator accuracy 0.2″ maximum measuring distance 80m
Understand the measurement step by step
- 01
Re-survey the rail foundation
- 02
Align the portal frame
- 03
Measure girders
- 04
Adjust rails
- 05
Re-verify before loading
- Mark nodes · Mark five nodes along a longitudinal line on the girder top flange at 200 mm spacing (total 800 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 200 mm sampling step.
- Align optics · Set up the autocollimator using the joint face on the portal crossbeam for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
- Integrate · Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
- Reverse run · Repeat the run in reverse over the same nodes, compare the two residual profiles and keep the raw angles together with before-and-after adjustment records.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Teaching example: straightness of a ship-to-shore crane girder
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching demonstration, not a real customer project: a 800 mm section of a ship-to-shore crane girder shows how interval angles from autocollimation are reconstructed into a height profile. The values are teaching assumptions and are not acceptance limits for port cranes.
Setup and preparation
Mark five nodes along a longitudinal line on the girder top flange at 200 mm spacing (total 800 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 200 mm sampling step.
Set up the autocollimator using the joint face on the portal crossbeam for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
Read and retain the raw angle of every interval rather than a smoothed display value, and log ambient temperature, time of measurement, and conditions such as solar temperature difference and wind-induced deflection.
Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
Example data and records
Interval angles: 1.8″, 1.2″, −0.9″, 0.4″.
Span and sampling step: 200 mm, four intervals; the first node is defined as 0 μm.
Cumulative node heights: 0.000, 1.745, 2.909, 2.036, 2.424 μm; residuals against the endpoint line: 0.000, 1.139, 1.697, 0.218, 0.000 μm.
Calculation steps
For each interval Δh = 200×1000×tan(θ·π/648000) μm. With the four angles this gives Δh ≈ 1.745, 1.164, −0.873, 0.388 μm; cumulative heights are 0.000, 1.745, 2.909, 2.036, 2.424 μm, residuals after removing the endpoint line are 0.000, 1.139, 1.697, 0.218, 0.000 μm and the peak-to-valley value is 1.697 μm.
Interpretation
For the given sampling and endpoint reference the residual peak-to-valley of a longitudinal line on the girder top flange is about 1.697 μm. It describes only the static geometry of this 800 mm line and is not an acceptance conclusion for port cranes.
Verification and pitfalls
Confirm that the reflector span matches the actual sampling step; the simple integration model cannot be applied when they differ.
A reverse run shows repeatability only and does not remove contact deformation or thermal drift of a ship-to-shore crane girder; solar temperature difference and wind-induced deflection must be assessed separately.
Any report must state the reference, evaluation algorithm, tolerance and measurement uncertainty.