MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Precision Moulds & Tooling
APPLICATION GUIDE

Precision Moulds & Tooling

Toolmaking machines, inspection plates, squares and mould-base mounting faces

Methods

Procedure

  1. Identify functional datums
  2. Define sampling
  3. Inspect surfaces and axes
  4. Assess clamping effects
  5. Verify and record

Complex freeform profiles need suitable coordinate or form equipment, not a single autocollimator angle.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗
STEP BY STEP

Understand the measurement step by step

  1. 01

    Identify functional datums

  2. 02

    Define sampling

  3. 03

    Inspect surfaces and axes

  4. 04

    Assess clamping effects

  5. 05

    Verify and record

Principle schematic · not to scale
1 / 4
  1. Supports and grid · Define the mounting face and three supports; mark a 3×3 equally spaced grid with normalized x and y coordinates −1, 0 and 1.
  2. Nine heights · Acquire nine height coordinates with a system suitable for the surface and range, recording clamping state rather than measuring only four corners.
  3. Plane and residuals · Fit the least-squares plane z=ax+by+c and retain the position of each residual; the balanced teaching matrix has fitted plane z=0.
  4. Refine and recheck · Locate the highest and lowest residuals and add points around suspected local high spots; inspect locating-face parallelism and axis squareness separately.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Nine-point mould-base grid and assembly-datum tutorial

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project. All numbers are constructed examples. A constructed rectangular base illustrates sampling, reference planes and local surface form. Height residuals are obtained with a suitable independent height measurement system, not by treating an autocollimator angle as height.

Setup and preparation

  • Define the mounting face and three supports; mark a 3×3 equally spaced grid with normalized x and y coordinates −1, 0 and 1.

  • Acquire nine height coordinates with a system suitable for the surface and range, recording clamping state rather than measuring only four corners.

  • Fit the least-squares plane z=ax+by+c and retain the position of each residual; the balanced teaching matrix has fitted plane z=0.

  • Locate the highest and lowest residuals and add points around suspected local high spots; inspect locating-face parallelism and axis squareness separately.

Example data and records

  • Residual rows in μm: [2,0,−2]; [0,0,0]; [−2,0,2].

  • The sums of residuals and their x- and y-weighted values are all zero.

  • Maximum residual +2 μm; minimum residual −2 μm.

Calculation steps

For this symmetric grid a=b=c=0; sampled least-squares residual PV=max(r)−min(r)=2−(−2)=4 μm.

Interpretation

The nine sampled points have a 4 μm residual peak-to-valley relative to the least-squares plane. This is not automatically a minimum-zone flatness result and cannot exclude defects between points.

Verification and pitfalls

  • Report clamped and freely supported states separately; do not combine their data.

  • Check probe contact, burrs and cleanliness; repeat suspect points instead of simply deleting them.

  • If minimum-zone evaluation is required, use the corresponding algorithm and adequate sampling coverage.