Procedure

  1. Establish stage coordinates
  2. Verify range and reference
  3. Sample each position
  4. Compare repeat runs
  5. Document the result

Geometric measurements do not by themselves establish lithography overlay or wafer process performance.

MEASUREMENT SCENARIOS

Typical measurement scenarios in this industry

Each scenario gives the object, tolerance range and method, ready to take to the selector.

Open in the atlas ↗
AssemblyStage Pitch & Yaw

Precision XY stage pitch and yaw

Strokes of 50–300 mm, often 1–5″. Sample every 10–20 mm across the travel and watch periodic components and reversal jumps.

Zhongji fully automatic autocollimators↗
AssemblyOptical Alignment

Viewport alignment into a vacuum chamber

Measuring through a window adds refraction and figure error. Correct for incidence angle and cross-check against an external reference mirror.

Wide-field electronic autocollimators↗
InspectionFlatness

Chuck and wafer-stage flatness

150–300 mm diameter, often 1–3 μm. For small high-precision areas an autocollimator with a short base avoids an interferometer's field limit.

Metrology autocollimator series↗
AssemblyPerpendicularity & Squareness

Dual-drive gantry synchronisation and orthogonality

Unequal drives yaw the beam. Two instruments, or one multi-channel unit, read both ends and give yaw and synchronisation error directly.

Zhongji automatic measurement series↗
InspectionRepeatability & Re-setup Verification

Vibration and repeatability check after installation

Sample one target for 10 min and read peak-to-peak angle noise and spectrum to judge foundation, isolators and air supply.

Zhongji high-speed dynamic autocollimators↗
InspectionStraightness

Two-plane straightness acceptance of stage guideways

Granite stage guideways with a few hundred millimetres of travel at 0.5 μm level; read at 50 mm spans and evaluate both planes by minimum zone.

Metrology autocollimator series↗
InspectionFlatness

Electrostatic chuck flatness

Chucks Ø 200–300 mm, 1–2 μm; measure at working temperature and clamping.

General-purpose electronic autocollimators↗
AssemblyLevelling and datum establishment

Lift pin synchronisation and table level

Asynchronous pins slip the wafer; check with displacement sensors or multi-point level.

General-purpose electronic autocollimators↗

Recommended instruments

STEP BY STEP

Understand the measurement step by step

  1. 01

    Establish stage coordinates

  2. 02

    Verify range and reference

  3. 03

    Sample each position

  4. 04

    Compare repeat runs

  5. 05

    Document the result

Principle schematic · not to scale
1 / 4
  1. Define Abbe geometry · Define travel direction, angular-channel signs and the effective offset from the measurement line to the point of interest. The 100 mm arm is an assumed example geometry, not a product specification.
  2. Read two static positions · Read both angular channels at P0 and P1 using the same settling condition, recording temperature and stage state.
  3. Subtract channel references · Subtract P0 readings separately from each channel to obtain pitch and yaw changes; raw channel zeros are not stage errors.
  4. Estimate and verify · Project the actual Abbe arm into each direction of interest to estimate position effects. Add a reverse run and a fixed-position time series to separate reversal differences from drift.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Semiconductor stage: angular change and Abbe-arm effects

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project. Pitch and yaw are compared at two static stage positions, then a defined effective 100 mm Abbe arm is used to estimate a directional position effect. This is not measured wafer-overlay or chip-inspection performance.

Setup and preparation

  • Define travel direction, angular-channel signs and the effective offset from the measurement line to the point of interest. The 100 mm arm is an assumed example geometry, not a product specification.

  • Read both angular channels at P0 and P1 using the same settling condition, recording temperature and stage state.

  • Subtract P0 readings separately from each channel to obtain pitch and yaw changes; raw channel zeros are not stage errors.

  • Project the actual Abbe arm into each direction of interest to estimate position effects. Add a reverse run and a fixed-position time series to separate reversal differences from drift.

Example data and records

  • P0: pitch +0.10″, yaw −0.10″.

  • P1: pitch +0.50″, yaw +0.20″.

  • Illustrative effective arm H=100 mm; its direction and sign must be established separately for each component.

Calculation steps

Changes are Δpitch=0.40″ and Δyaw=0.30″. With e≈Hθrad, a 100 mm arm gives directional effects of approximately 0.193925 μm and 0.145444 μm.

Interpretation

These are separate directional components for a specified geometry. They cannot simply be added as overlay error or treated as total stage positioning error.

Verification and pitfalls

  • Determine the actual Abbe arm and channel mapping from the mechanical measurement model.

  • Roll and translational errors are excluded from this two-channel angle example.

  • Static station results do not replace high-speed scan, vibration or process-state verification.