MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Steel and Metallurgy Equipment
APPLICATION GUIDE

Steel and Metallurgy Equipment

Mill housings, roll chocks, continuous-casting curved segments, roller tables, shear frames, converter trunnion rings

Methods

Procedure

  1. Establish maintenance datums
  2. Measure housings
  3. Measure centerlines
  4. Adjust shim plates
  5. Verify and record

Geometric checks do not replace hot alignment, rolling-force and stiffness tests, roll-train vibration analysis, or strip-shape acceptance by trial rolling.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Establish maintenance datums

  2. 02

    Measure housings

  3. 03

    Measure centerlines

  4. 04

    Adjust shim plates

  5. 05

    Verify and record

Principle schematic · not to scale
1 / 4
  1. Mark nodes · Mark five nodes along a vertical line on the window face at 100 mm spacing (total 400 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 100 mm sampling step.
  2. Align optics · Set up the autocollimator using the machined housing base for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.
  3. Integrate · Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.
  4. Reverse run · Repeat the run in reverse over the same nodes, compare the two residual profiles and keep the raw angles together with before-and-after adjustment records.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Teaching example: straightness of a mill housing window

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: a 400 mm section of a mill housing window liner shows how interval angles from autocollimation are reconstructed into a height profile. The values are teaching assumptions and are not acceptance limits for steel and metallurgy.

Setup and preparation

  • Mark five nodes along a vertical line on the window face at 100 mm spacing (total 400 mm) and define a positive angle as an upward step to the next node; the reflector-base span equals the 100 mm sampling step.

  • Set up the autocollimator using the machined housing base for coarse alignment, keep the readings near mid-range and confirm that the reflector base keeps its orientation while it is moved from node to node.

  • Read and retain the raw angle of every interval rather than a smoothed display value, and log ambient temperature, time of measurement, and conditions such as residual heat and oil contamination.

  • Integrate the intervals into five node heights, use the line through the first and last nodes as the reference, compute the residuals and then repeat the run in reverse over the same nodes.

Example data and records

  • Interval angles: 1.2″, −1.5″, −0.8″, 0.6″.

  • Span and sampling step: 100 mm, four intervals; the first node is defined as 0 μm.

  • Cumulative node heights: 0.000, 0.582, −0.145, −0.533, −0.242 μm; residuals against the endpoint line: 0.000, 0.642, −0.024, −0.351, 0.000 μm.

Calculation steps

For each interval Δh = 100×1000×tan(θ·π/648000) μm. With the four angles this gives Δh ≈ 0.582, −0.727, −0.388, 0.291 μm; cumulative heights are 0.000, 0.582, −0.145, −0.533, −0.242 μm, residuals after removing the endpoint line are 0.000, 0.642, −0.024, −0.351, 0.000 μm and the peak-to-valley value is 0.994 μm.

Interpretation

For the given sampling and endpoint reference the residual peak-to-valley of a vertical line on the window face is about 0.994 μm. It describes only the static geometry of this 400 mm line and is not an acceptance conclusion for steel and metallurgy.

Verification and pitfalls

  • Confirm that the reflector span matches the actual sampling step; the simple integration model cannot be applied when they differ.

  • A reverse run shows repeatability only and does not remove contact deformation or thermal drift of a mill housing window liner; residual heat and oil contamination must be assessed separately.

  • Any report must state the reference, evaluation algorithm, tolerance and measurement uncertainty.