Principle
An autocollimator measures reflector angles relative to its optical axis, which is not necessarily vertical; column verticality therefore needs an independent horizontal datum. The usual practice: first establish the gravity reference by reading a precision or electronic level on the reflector base or a small bridge at a reference position; then move the reflector along the column face and read each tilt with the autocollimator. The tilt from vertical at each station combines the autocollimator reading with the level datum; integration yields the face profile relative to the plumb line, and its inclination to the reference plumb line is the verticality error.
Preparation
Clean the column guide faces, confirm the measurement line and plan station spacing as an integer multiple of the base span. Verify the calibration of level and autocollimator; ensure the reflector base seats well on the column. Measure only after thermal equilibrium, avoiding immediately after shutdown or one-sided sunshine. Record temperature and machine state.
Workflow diagram
Procedure
- Define the line and station spacing on the column, mark positions and record the span.
- Place the level on the reflector base or bridge at the start and read the attitude as the gravity reference.
- Align the autocollimator and step the reflector up the column, recording each reading.
- Re-place the level on the base at key stations, at least start and end, to track datum drift or structural tilt changes.
- Combine autocollimator readings with the level reference into tilt-from-vertical, then integrate to the profile.
- Evaluate verticality against the start tangent or the plumb line, reporting the full-height inclination and local deviations separately.
Calculation
Per-station conversion as before: θrad=θ″·π/648000 and Δh=L·tan(θrad). Combining with the level requires care with frames: with level reading αL (from horizontal) and autocollimator reading θA (from the optical axis), the tilt from vertical follows the layout geometry (example: βi=αL,i−θA,i, sign defined by mounting). Verticality is expressed as the full-height inclination γ=arctan[(zn−z1)/H], H being the start-to-end height (illustrative relation; the actual layout governs).
Illustrative example
Teaching data, not measured: a 2 m column line with a 200 mm span and 10 stations. The integrated profile peaks at +0.02 mm from the start tangent (demonstration) and the end-to-end rise is +0.012 mm, giving an overall inclination of about γ=arctan(0.012/2000)≈1.2×10⁻³ rad (illustrative conversion). No real column is implied.
Limitations
- Treating the autocollimator axis itself as vertical without a level reference.
- Thermal imbalance such as one-sided sunshine yielding heat distortion rather than installation error.
- Poor seating of the reflector base mixing contact error into local readings.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.