MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Perpendicularity & Squareness
MEASUREMENT METHOD

Perpendicularity & Squareness

Distinguish perpendicularity of physical features from squareness between the mean directions of motion axes.

Principle

A calibrated right-angle reference connects two directions while retaining orientation and form information.

Preparation

Specify the datum, measurement length, plane and feature type. Use a calibrated optical square or an appropriate right-angle reference.

Workflow diagram

01Identify whether the requirement concerns an angular r02Measure the first axis or datum feature03Transfer the direction through a calibrated right-angl04Evaluate axis squareness as a direction difference05Repeat after reversal or re-setup and record reference

Procedure

  1. Identify whether the requirement concerns an angular relationship or a complete datum-constrained tolerance zone.
  2. Measure the first axis or datum feature, retaining its direction and form data.
  3. Transfer the direction through a calibrated right-angle reference and measure the second feature.
  4. Evaluate axis squareness as a direction difference; evaluate feature perpendicularity from all relevant points under the specified datum constraint.
  5. Repeat after reversal or re-setup and record reference corrections, measured length and results.

Calculation

Axis squareness deviation δ=α−90°. For a small directional error, e≈Lδrad; surface perpendicularity additionally requires datum-constrained point evaluation.

Illustrative example

Schematic · not measured data
Schematic relationship of two axes and a right-angle reference, not a customer acceptance record.

Illustration: 2″ over 500 mm corresponds to about 4.85 μm of directional tilt, excluding surface form.

Limitations

  • A 90-degree relationship between fitted lines does not prove full-surface perpendicularity.
  • The right-angle reference error must be corrected or included in uncertainty.
  • Do not remove all directional information before comparing axes.

Reporting

Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.

Method reference ↗ Method reference ↗ 
STEP BY STEP

Understand the measurement step by step

Principle schematic · not to scale
1 / 4
  1. Define right-angle datum · Define both directions, the sign convention and the angle reference; distinguish travel directions from material surfaces.
  2. Record corrected angle · Assume a corrected included angle of 90°+3 arcsec and record the reference calibration; no unspecified correction is added.
  3. Show tilt · Keep one direction fixed in the diagram and show the other slightly tilted over an effective length of 300 mm.
  4. Convert and qualify · Calculate the equivalent offset with the tangent relationship; require separate datum, tolerance-zone and uncertainty definitions for acceptance.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

From angular squareness error to lateral offset

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: an appropriate angular reference has established the deviation of two travel directions from 90°. Convert it over 300 mm without treating that conversion as a complete surface-perpendicularity test.

Setup and preparation

  • Define both directions, the sign convention and the angle reference; distinguish travel directions from material surfaces.

  • Assume a corrected included angle of 90°+3 arcsec and record the reference calibration; no unspecified correction is added.

  • Keep one direction fixed in the diagram and show the other slightly tilted over an effective length of 300 mm.

  • Calculate the equivalent offset with the tangent relationship; require separate datum, tolerance-zone and uncertainty definitions for acceptance.

Example data and records

  • Nominal included angle: 90°.

  • Assumed corrected angle: 90°+3 arcsec.

  • Conversion length: 300 mm.

Calculation steps

δ=3·π/648000 rad; e=300·tanδ·1000=4.363323 μm. For small δ, e≈Lδ; multiply by 1000 to convert millimetres to micrometres.

Interpretation

The directional model gives an equivalent lateral offset of about +4.363 μm at 300 mm. Surface form, axis construction and full perpendicularity evaluation are outside this conversion.

Verification and pitfalls

  • Use 90°, not 0°, as the nominal angle and convert arcseconds to radians.

  • Verify the relation between the angle reference and the tested directions, including a reversal check.

  • Without tolerance, uncertainty and a decision rule, no conformance conclusion is available.