Principle
A through-thickness gradient bends a part toward the cooler side, the hotter face expanding more. For a uniform beam of length L, thickness d and expansion coefficient α, a top-bottom difference ΔT gives a curvature radius of roughly R=d/(α·ΔT) and a maximum deflection of about f=L²/(8R) (simplified simply-supported model, self-weight neglected). The autocollimator tilt sequence thus acquires an approximately quadratic component. Compensation places sensors on the top and bottom (or key positions), computes the bending profile from ΔT via the model and subtracts it, or waits for thermal equilibrium and re-measures to verify. Where assumptions mismatch the real constraints, the compensation must be experimentally validated.
Preparation
Place temperature sensors on the top and bottom faces (or both sides through the thickness) and in the room, recording positions. Calibrate the sensors or at least cross-check them. Synchronize temperature logging with the measurement and record timestamps. Confirm the support configuration, since deflection depends on it. Do not switch heat sources during the run.
Workflow diagram
Procedure
- Mount sensors on both sides through the thickness and in the room; record positions and check consistency.
- Record the initial temperature distribution before measuring, confirming near-steady state or logging the trend.
- Perform the angular measurement synchronised with temperature logging in one timestamp system.
- Compute the bending model from the temperature difference: R=d/(α·ΔT), solving the deflection f(x) for the support form.
- Convert the model profile to an equivalent tilt sequence and overlay it on the measured one to assess agreement.
- Subtract the model component (or re-measure after thermal equilibrium) and report pre- and post-compensation results with environment data.
Calculation
Simplified model: radius R=d/(α·ΔT), with thickness d in mm, expansion coefficient α (about 11.5×10⁻⁶/K for steel, example) and difference ΔT. A simply supported part has a maximum deflection f=L²/(8R) and an approximately linear tilt θ(x)≈x/R (rad). The compensation is subtracted from the measured profile with the correct sign. Model uncertainty follows from ΔT uncertainty and assumptions and must be reported: δf/f≈δ(ΔT)/ΔT (first-order propagation, illustrative).
Illustrative example
Teaching data, not measured: a steel guideway with L=2 m, d=200 mm, top-bottom difference ΔT=0.5 K and α=11.5×10⁻⁶/K. Then R=200/(11.5×10⁻⁶·0.5)≈3.5×10⁷ mm and f=L²/(8R)=(2000)²/(8·3.5×10⁷)≈0.014 mm≈14 μm (demonstration). A systematic error of this order enters the profile directly if uncompensated. The figures are model arithmetic, not measurements.
Limitations
- Taking simplified beam-model values as truth without verification at thermal equilibrium.
- Sensors measuring one point or only the air miss the through-thickness gradient.
- Heat-source changes during the run break the correspondence between model and measurement.
Reporting
Retain raw data, datum definition, temperature, repeatability, algorithm and uncertainty. Illustrations are not test results.