MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Granite plate grid flatness
DOWNLOADABLE MEASUREMENT PLAN

Granite plate grid flatness

Flatness of surface plates, machine tables and large bases, including grid design, closure checks and before/after lapping.

Instruments

Procedure

Calculation

Δh = L·tanθ between nodes; closure beyond the threshold means re-measure the path.

Reporting

Limitations

A sparse grid misses local defects; flatness does not cover hardness or roughness.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Design the grid and closed paths; define support points.

  2. 02

    Stabilise the plate thermally and set it on three or four supports.

  3. 03

    Measure line by line on a common height datum and check closure.

  4. 04

    Evaluate by least squares and minimum zone separately, stating which applies.

  5. 05

    Re-measure the same grid after lapping and report the difference map.

Principle schematic · not to scale
1 / 5
  1. Step 1 · Design the grid and closed paths; define support points.
  2. Step 2 · Stabilise the plate thermally and set it on three or four supports.
  3. Step 3 · Measure line by line on a common height datum and check closure.
  4. Step 4 · Evaluate by least squares and minimum zone separately, stating which applies.
  5. Step 5 · Re-measure the same grid after lapping and report the difference map.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Worked nine-point grid flatness example on an 800×800 mm plate

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching example: nine nodes on a 400 mm grid over 800×800 mm; a least-squares plane is removed and the residual range is reported as flatness. Synthetic data.

Setup and preparation

  • Design the grid and closed paths; define support points.

  • Stabilise the plate thermally and set it on three or four supports.

  • Measure line by line on a common height datum and check closure.

  • Evaluate by least squares and minimum zone separately, stating which applies.

Example data and records

  • Node heights in µm: +0, +1, +2, +0, +1, +3, -1, +0, +2 in 3×3 row order.

  • Fitted plane slopes a = −0.00083, b = 0.00333 µm/mm.

  • Residuals in µm: 0.111, −0.222, −0.556, 0.444, 0.111, 0.778, −0.222, −0.556, 0.111.

Calculation steps

Least-squares plane z = z̄ + a(y−ȳ) + b(x−x̄); residual range = 1.333 µm. A coarse grid misses local waviness between nodes.

Interpretation

Flatness is about 1.333 µm with a high lower-right corner. Nine points only indicate a trend; formal acceptance needs the diagonal method and the specified point density.

Verification and pitfalls

  • Cover corners and edges; that is where deviation peaks.

  • Measure on the specified free supports; shimming hides the true form.

  • Log temperature and scan direction; granite anisotropy is small but not zero.