Large slewing bearing and flange flatness
Flatness and parallelism of mounting faces on wind, construction and large rotary equipment.
Instruments
- Autocollimator or laser tracker
- Bridge and equal-height blocks
- Multi-point temperature log
Procedure
- Confirm diameter, bolt preload state and measurement condition (free or preloaded).
- Place stations around and across the face, covering bolt spans.
- Measure heights or angles on one datum.
- Evaluate flatness and flange parallelism; mark local highs.
- Re-measure after tightening and compare states.
Calculation
Flatness is the extreme deviation from the fitted plane; parallelism is the extreme difference between corresponding points.
Reporting
- Stations cover bolt spans
- Free and preloaded measured
- Gradient logged
- Local highs marked
Limitations
Thin flanges deform elastically under preload; free-state results are not the installed condition.
Understand the measurement step by step
- 01
Confirm diameter, bolt preload state and measurement condition (free or preloaded).
- 02
Place stations around and across the face, covering bolt spans.
- 03
Measure heights or angles on one datum.
- 04
Evaluate flatness and flange parallelism; mark local highs.
- 05
Re-measure after tightening and compare states.
- Step 1 · Confirm diameter, bolt preload state and measurement condition (free or preloaded).
- Step 2 · Place stations around and across the face, covering bolt spans.
- Step 3 · Measure heights or angles on one datum.
- Step 4 · Evaluate flatness and flange parallelism; mark local highs.
- Step 5 · Re-measure after tightening and compare states.
Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.
Worked flatness example on a Ø3000 mm slewing-ring flange
Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.
Example task
Teaching example: twelve equally spaced points on a Ø3000 mm flange; flatness and parallelism are derived from heights, with preload change recorded separately.
Setup and preparation
Confirm diameter, bolt preload state and measurement condition (free or preloaded).
Place stations around and across the face, covering bolt spans.
Measure heights or angles on one datum.
Evaluate flatness and flange parallelism; mark local highs.
Example data and records
Point deviations in µm: +0, +2, +3, +1, -1, -2, -1, +0, +1, +2, +1, +0 at 30° steps.
After removing the mean the range is 5 µm.
Re-measure after preload; the change is recorded separately, not folded into flatness.
Calculation steps
Flatness is the maximum deviation from the fitted plane; the residual range here is 5 µm. A three-point datum gives a larger value and must be named.
Interpretation
The deviation sits in two opposite quadrants, indicating warp rather than tilt. Shims remove tilt, not warp.
Verification and pitfalls
Point count and distribution must match the drawing or agreement; at least twelve for rings.
Preload force and sequence change the result; log torque and sequence.
Flatness and parallelism are separate criteria.