MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Bed guideway inspection plan for a roll grinder
DOWNLOADABLE MEASUREMENT PLAN

Bed guideway inspection plan for a roll grinder

For straightness and twist of the extra-long guideways of a roll grinder bed (12000 mm, example/teaching data). Multi-segment spliced measurement is used; the first station of each segment is re-read to monitor drift, with the temperature field and instrument relocation error tightly controlled.

Instruments

Procedure

Calculation

Δh=L·tanθ; with L=200 mm, 1″≈0.970 μm (example/teaching data). Splicing minimises squared height differences in the overlaps; twist = roll angle × bridge span B; thermal drift is corrected linearly from each segment's re-read difference.

Reporting

Limitations

Does not cover hot-state grinding deformation or bed deformation under roll weight; the measurement cycle is long, so the report must state the environment window and the temperature correction method.

STEP BY STEP

Understand the measurement step by step

  1. 01

    Confirm the 12000 mm bed (example), segmentation (6×2000 mm), 200 mm span and endpoint-line datum agreement.

  2. 02

    Level the bed, let it settle and record the multi-point temperature field.

  3. 03

    Measure segment by segment with 3 overlapping intervals between neighbours; read roll at each station with the bridge simultaneously.

  4. 04

    At the end of each segment re-read its first station for drift; if the drift exceeds the criterion (1″, example), re-measure that segment.

  5. 05

    Register the overlaps by least squares into the full profile and evaluate straightness and twist via Δh=L·tanθ integration.

  6. 06

    Reverse-repeat the full length once and compare splice-zone consistency.

  7. 07

    Deliver the full profile, twist curve, temperature records and raw segment data.

Principle schematic · not to scale
1 / 5
  1. Oil temperature · Wait for hydrostatic oil temperature to settle.
  2. Head station · Autocollimator fixed at the bed head.
  3. Guide segments · The 200 mm bridge walks the V-guide.
  4. Log readings · Pitch values recorded per segment.
  5. Straightness · Cumulative conversion gives straightness.

Teaching animation: follow the stations and reference directions. Do not read dimensions or angles from the schematic.

WORKED EXAMPLE

Roll Grinder Bed Guide Inspection · Tutorial Case

Teaching example with assumed data, not a customer project, instrument accuracy claim or acceptance result.

Example task

Teaching demonstration, not a real customer project: first three segments of a long-travel straightness survey on a roll grinder bed guide; data are instructional settings.

Setup and preparation

  • Clean the bed guide and confirm hydrostatic oil temperature is stable

  • Fix the autocollimator on a stand at the head of the bed

  • Survey with a 200 mm bridge along the V-guide step by step

  • Record the pitch reading per segment

  • Cumulate three segments for straightness results

Example data and records

  • Bridge span L=200 mm; segment 1 autocollimator reading θ₁=+1″

  • Segment 2 autocollimator reading θ₂=+0.5″

  • Segment 3 autocollimator reading θ₃=-1.5″

Calculation steps

Height conversion: Δh = L·tan(θ·π/648000)×1000 (μm). Segment 1: 200×tan(+1″)=+0.97 μm; Segment 2: 200×tan(+0.5″)=+0.48 μm; Segment 3: 200×tan(-1.5″)=-1.45 μm. Cumulative heights: 0→+0.97→+1.45→+0.00 μm; peak-to-valley PV=+1.45−(+0.00)=+1.45 μm.

Interpretation

Tutorial result PV≈1.45 μm, demonstrating long-travel guide inspection on the grinder bed.

Verification and pitfalls

  • Measure only after hydrostatic oil temperature stabilises

  • Bridge contacts the guide without gaps

  • Check instrument zero before surveying