Rule out geometry first
Static rail parallelism and beam tilt measured 0.008 mm/m, too small to explain 45 μm.
Encoder direction and resolution matched on both sides.
Then the dynamics
Synchronous logging showed one side lagging about 3 ms during acceleration and overshooting on deceleration.
Match velocity loops first, then tune feed-forward.
Re-test
After tuning: 8 μm low speed, 18 μm at working speed.
Case workflow, animated
- Confirm the task and datum
- Lay out stations by span
- Acquire readings and convert
- Evaluate and verify
The animation follows the station layout and calculation order of this case. Values are teaching data.
Teaching example. Dual-drive tuning must be done by the maker or authorised personnel; back up parameters first.
Recommended instruments

Dual-axis autocollimator, accuracy 0.1″, range 30 m

Dual-axis autocollimator, accuracy 1″, range 40 m