MICROCRE / OPTICAL METROLOGY400-812-7833  ·  SHANGHAI
研润 WHW
MICROCREPRECISION IN EVERY ANGLE
Home / Glass annealing lehr rollers: six stations, 0.004 mm closure
CASE 26 · TEACHING DATA

Glass annealing lehr rollers: six stations, 0.004 mm closure

Uneven lehr rollers imprint periodic waves on the glass ribbon. Accumulating station angles gives a height profile and identifies the rollers to adjust.

ObjectLehr roller table, 1500 mm span, six stations
InstrumentElectronic level, cross-checked with autocollimator
Readings0 / +3.1 / +1.4 / −0.8 / −2.2 / +0.4 ″
CriterionAdjacent rollers ≤ 0.02 mm, section ≤ 0.08 mm
h_i = sum L tan(theta)

Angle to height

Δh = 1500 × tanθ per station; accumulated: +0.000, +0.000, +0.023, +0.033, +0.027, +0.011, +0.014 mm.

Total range 0.033 mm is inside 0.08 mm, but a reversal of +10 μm between stations 2 and 3 marks a high roller.

Closure check

Returning to the start, +0.4″ corresponds to 0.003 mm, effectively closed.

A larger closure points to a knocked base, airflow or drift.

Adjustment

Adjust the single offending roller rather than re-setting the section; re-measure with the same span.

Case workflow, animated

Bubble centred = level referenceAutocollimatorLevel sets the datum, autocollimator reads angleSchematic · not to scale · not measured data
1 / 4
  1. Confirm the task and datum
  2. Lay out stations by span
  3. Acquire readings and convert
  4. Evaluate and verify

The animation follows the station layout and calculation order of this case. Values are teaching data.

ConclusionRange 0.033 mm concentrates near station 3; adjusting one roller restores closure at the 0.004 mm level.

Teaching data. Lehr adjustment requires a stopped line and hot-work procedures.