Why two sections
One section gives offset at that height only and cannot separate translation from tilt about the base. Translation is shimmed; tilt needs re-machining.
Subtract the two readings and divide by the spacing for tilt; average them for the mean offset.
Work the numbers
Mean offset = 60 μm against 100 μm: pass.
Tilt = 27.5″ against 30″: pass, with only 8% margin.
How to use the two numbers
Offset within limits: correct with shims. Tilt passes but with little margin, so tighten diagonally and re-measure after final torque; tightening order shifts tilt at the 10″ level.
Case workflow, animated
- Confirm the task and datum
- Lay out stations by span
- Acquire readings and convert
- Evaluate and verify
The animation follows the station layout and calculation order of this case. Values are teaching data.
Teaching data. Use the OEM assembly specification for acceptance; this is not an acceptance result for any machine.